Safety information search results
Filter your results
Building or structure type
- Bridges (12)
- (-)
Buildings
(436)
- Agricultural buildings (9)
- Commercial (37)
- Consequence Class 3 buildings (3)
- Education, science & art buildings (25)
- Health care (8)
- Higher-risk buildings (5)
- Industrial buildings (16)
- Laboratory buildings (1)
- LPS buildings (3)
- Nuclear & energy buildings (1)
- Public, religious & civic buildings (13)
- Recreational buildings (9)
- Residential (119)
- Stadiums (6)
- Storage buildings (11)
- Tall buildings (22)
- Theatres & other entertainment buildings (11)
- Transport buildings (6)
- Buried pipes & culverts (1)
- Car parks (18)
- Flats & apartments (41)
- Floating structures (1)
- Freestanding walls (3)
- Hotels & hostels (5)
- Houses (42)
- Marine structures (2)
- Masts & towers (3)
- Railways (4)
- Reservoirs & dams (1)
- Retaining structures (11)
- Roads (2)
- Sewers (1)
- Temporary structures (6)
Building height
- 5m or higher, but lower than 11m (14)
- 5m or higher, but lower than 12m (1)
- 11m or higher, but lower than 18m (13)
- 18m or higher, but lower than 30m (9)
- 30m or higher (5)
- CROSS-UK [sub-heading only] (21)
- CROSS-US [sub-heading only] (2)
- Lower than 5m (1)
- Lower than 5m (1)
- Low rise (2-4 stories) (1)
- Single storey (6)
Materials
Project or lifecycle stage
Design
- BIM (2)
- Computational design (9)
- Design: quality management (41)
- Design calculations (49)
- Design conceptualisation (21)
- Design detailing (76)
- Design drawings (22)
- Design loads (75)
- Design software (19)
- Dynamics (9)
- Fire safety design (14)
- Resilience (16)
- Robustness (40)
- Structural design (78)
- Sustainability (6)
Codes, standards & regulations
Fire incident response
Project type
- Alteration & conversion project (34)
- Assessment project [sub-heading only] (14)
- Conservation & restoration project (2)
- Construction project [sub-heading only] (163)
- Demolition project (10)
- Excavation (7)
- Extension project (16)
- Fire safety assessment (2)
- Groundworks project (1)
- Maintenance project (2)
- New build (84)
- Refurbishment (15)
- Remediation project (18)
- Repair project (4)
- Strengthening project (5)
- Structural assessment (21)
- Underpinning project (4)
Construction period
Method of construction
Elements & systems
- Arch (2)
- Balconies (16)
- Balustrades (18)
- Basements (13)
- Beams (50)
- Bracing (16)
- Canopies (7)
- Ceilings (22)
- Cladding (27)
- Columns (34)
- Fasteners & connections (93)
- Fences (1)
- Fire exit doors (2)
- Fire protection (14)
- Foundations (20)
- Insulation (9)
- Light gauge steel framing (5)
- Lintels (4)
- Padstones (5)
- Parapets (10)
- PV panels (1)
- Roofs (67)
- Sandwich panels (2)
- Shear walls (3)
- Signs (2)
- Slabs (41)
- Tendons (1)
- Trusses (8)
- Wall head restraints (3)
- Walls (68)
- Wall ties (12)
- Wind posts (1)
Plant & equipment
Utilities
Safety reporting
Organisations
Business practice
Content type
- CROSS-AUS Newsletter 1 (1)
- CROSS-AUS Newsletter 2 (2)
- CROSS-AUS Newsletter 3 (2)
- CROSS-AUS Newsletter 8 (2)
- CROSS-AUS [sub-heading only] (4)
- CROSS-UK Newsletter 1 (6)
- CROSS-UK Newsletter 2 (6)
- CROSS-UK Newsletter 3 (3)
- CROSS-UK Newsletter 4 (2)
- CROSS-UK Newsletter 5 (6)
- CROSS-UK Newsletter 6 (5)
- CROSS-UK Newsletter 7 (5)
- CROSS-UK Newsletter 8 (2)
- CROSS-UK Newsletter 9 (4)
- CROSS-UK Newsletter 10 (6)
- CROSS-UK Newsletter 11 (3)
- CROSS-UK Newsletter 12 (7)
- CROSS-UK Newsletter 13 (4)
- CROSS-UK Newsletter 14 (2)
- CROSS-UK Newsletter 15 (3)
- CROSS-UK Newsletter 17 (4)
- CROSS-UK Newsletter 18 (2)
- CROSS-UK Newsletter 19 (4)
- CROSS-UK Newsletter 20 (6)
- CROSS-UK Newsletter 21 (4)
- CROSS-UK Newsletter 22 (1)
- CROSS-UK Newsletter 23 (7)
- CROSS-UK Newsletter 24 (2)
- CROSS-UK Newsletter 25 (2)
- CROSS-UK Newsletter 26 (5)
- CROSS-UK Newsletter 28 (1)
- CROSS-UK Newsletter 29 (2)
- CROSS-UK Newsletter 30 (3)
- CROSS-UK Newsletter 31 (5)
- CROSS-UK Newsletter 32 (5)
- CROSS-UK Newsletter 33 (7)
- CROSS-UK Newsletter 34 (4)
- CROSS-UK Newsletter 35 (4)
- CROSS-UK Newsletter 36 (2)
- CROSS-UK Newsletter 37 (5)
- CROSS-UK Newsletter 38 (4)
- CROSS-UK Newsletter 39 (4)
- CROSS-UK Newsletter 40 (4)
- CROSS-UK Newsletter 41 (6)
- CROSS-UK Newsletter 42 (4)
- CROSS-UK Newsletter 43 (4)
- CROSS-UK Newsletter 44 (2)
- CROSS-UK Newsletter 45 (4)
- CROSS-UK Newsletter 46 (4)
- CROSS-UK Newsletter 47 (6)
- CROSS-UK Newsletter 48 (6)
- CROSS-UK Newsletter 49 (6)
- CROSS-UK Newsletter 50 (6)
- CROSS-UK Newsletter 51 (6)
- CROSS-UK Newsletter 52 (3)
- CROSS-UK Newsletter 53 (3)
- CROSS-UK Newsletter 54 (6)
- CROSS-UK Newsletter 55 (5)
- CROSS-UK Newsletter 56 (4)
- CROSS-UK Newsletter 57 (4)
- CROSS-UK Newsletter 58 (8)
- CROSS-UK Newsletter 59 (4)
- CROSS-UK Newsletter 60 (6)
- CROSS-UK Newsletter 61 (3)
- CROSS-UK Newsletter 62 (7)
- CROSS-UK Newsletter 64 (9)
- CROSS-UK Newsletter 65 (8)
- CROSS-UK Newsletter 67 (10)
- CROSS-UK [sub-heading only] (231)
- CROSS-US Newsletter 1 (3)
- CROSS-US Newsletter 2 (6)
- CROSS-US Newsletter 3 (5)
- CROSS-US [sub-heading only] (8)
- CROSS Feature Article (1)
- CROSS Newsletter (141)
- CROSS Safety Alert (12)
- CROSS Safety Report (407)
- CROSS Theme Page (1)
- CROSS Topic Paper (8)
- News [sub-heading only] (45)
- Safety information from CROSS [sub-heading only] (4)
- Safety information [sub-heading only] (5)
- Third party content (7)
- Third party content (5)
CROSS regions
Structural safety of reinforced autoclaved aerated concrete (RAAC) planks
A Theme Page to raise awareness of and encourage knowledge sharing on the structural safety of RAAC planks.
CROSS Theme Page
Region: CROSS-UK, CROSS-AUS, CROSS-US
Snow drift implications due to building extension
Part of a roof collapsed in a factory and warehouse facility shortly after a storm event due to snow drift loads.
13 December 2022
CROSS Safety Report
Report ID: 947
Region: CROSS-UK
Collapse of external brick wall during demolition works
A section of an external brick wall of a building collapsed suddenly and unexpectedly part way through a demolition contract.
13 December 2022
CROSS Safety Report
Report ID: 875
Region: CROSS-UK
Concern over concrete test methods used on site
A reporter is concerned about the test method a contractor uses to justify the strength of concrete placed on site.
13 December 2022
CROSS Safety Report
Report ID: 840
Region: CROSS-UK
Essential consideration of ‘soft hazards’ on civil and building engineering projects
A check-list for all those engaged in structural or fire engineering design.
7 December 2022
Third party content
Inadequate design for basement works
An inadequate structural design for alterations to a basement led to structural distress within a substantial five-storey townhouse.
21 November 2022
CROSS Safety Report
Report ID: 1132
Region: CROSS-UK
Share your knowledge
Your report will make a difference. It will help to create positive change and improve safety.
Our secure and confidential safety reporting system gives professionals the opportunity to share their experiences to help others.
Concerns over execution class categorisation of steel pedestrian bridge
A reporter is concerned in respect of the steelwork execution class, and quality management arrangements, applied to the construction of a public access pedestrian bridge.
21 November 2022
CROSS Safety Report
Report ID: 1149
Region: CROSS-UK
Critical welding of structural steelwork missed
The designer of a steelwork roof frame found a critical fabrication error when inspecting steelwork on site before it was erected.
21 November 2022
CROSS Safety Report
Report ID: 1126
Region: CROSS-UK
Fire spread through balconies
This report highlights that the extensive use of combustible materials in the construction of balconies can result in fire spread over the external wall to an extent which is inadequate for building safety, even buildings less than 18m.
17 November 2022
CROSS Safety Report
Report ID: 1052
Region: CROSS-UK
Do planning applications hinder safety improvements?
A potential issue about the reconstruction of a structurally inadequate external fire escape from a building has been raised with CROSS.
17 November 2022
CROSS Safety Report
Report ID: 1043
Region: CROSS-UK