Safety information search results
Filter your results
Building or structure type
- Bridges (26)
- Buildings
(203)
- Agricultural buildings (8)
- Car parks (7)
- Commercial (20)
- Consequence Class 3 buildings (3)
- Education, science & art buildings (11)
- Health care (2)
- Higher-risk buildings (4)
- Industrial buildings (5)
- Laboratory buildings (1)
- Nuclear & energy buildings (1)
- Public, religious & civic buildings (7)
- Recreational buildings (6)
- Residential (52)
- Stadiums (2)
- Storage buildings (6)
- Tall buildings (12)
- Theatres & other entertainment buildings (5)
- Transport buildings (2)
- Buried pipes & culverts (2)
- Floating structures (1)
- Freestanding walls (2)
- Marine structures (2)
- Masts & towers (7)
- Offshore structures (1)
- Railways (4)
- Reservoirs & dams (2)
- Retaining structures (14)
- Roads (5)
- Sewers (2)
- Temporary structures (14)
- Tunnels (1)
Materials
Project or lifecycle stage
Design
- BIM (5)
- Computational design (12)
- Design: quality management (61)
- Design calculations (74)
- Design conceptualisation (27)
- Design detailing (84)
- Design drawings (29)
- Design loads (77)
- Design software (33)
- Dynamics (6)
- Fire safety design (15)
- Resilience (14)
- Robustness (37)
- Structural design (102)
- Sustainability (6)
Codes, standards & regulations
Fire incident response
Project type
- Alteration & conversion project (21)
- Assessment project [sub-heading only] (7)
- Conservation & restoration project (2)
- Construction project [sub-heading only] (103)
- Demolition project (1)
- Excavation (5)
- Extension project (13)
- Groundworks project (1)
- Maintenance project (3)
- New build (48)
- Refurbishment (15)
- Remediation project (11)
- Repair project (6)
- Strengthening project (3)
- Structural assessment (15)
- Underpinning project (2)
Construction period
Method of construction
Elements & systems
- Arch (2)
- Balconies (4)
- Balustrades (10)
- Basements (7)
- Beams (44)
- Bracing (12)
- Cables (1)
- Canopies (1)
- Ceilings (8)
- Cladding (20)
- Columns (26)
- Fasteners & connections (72)
- Fences (1)
- Fire protection (9)
- Foundations (16)
- Insulation (8)
- Light gauge steel framing (6)
- Padstones (2)
- Parapets (4)
- PV panels (3)
- Roofs (43)
- Sandwich panels (2)
- Shear walls (2)
- Signs (1)
- Slabs (26)
- Trusses (9)
- Walls (41)
- Wall ties (4)
Plant & equipment
Utilities
Safety reporting
Organisations
- CROSS-AUS [sub-heading only] (7)
- CROSS-UK [sub-heading only]
(29)
- Building Control Northern Ireland (2)
- Building Safety Regulator (BSR) (1)
- Environment Agency (1)
- Fire and Rescue Service (FRS) (3)
- Health and Safety Executive (HSE) (8)
- Local Authority Building Control (LABC) (12)
- Local Authority Building Standards Scotland (LABSS) (2)
- Scottish Environment Protection Agency (SEPA) (1)
Business practice
Content type
- CROSS-AUS Newsletter 1 (1)
- CROSS-AUS Newsletter 2 (2)
- CROSS-AUS Newsletter 3 (4)
- CROSS-AUS Newsletter 4 (3)
- CROSS-AUS Newsletter 5 (2)
- CROSS-AUS [sub-heading only] (10)
- CROSS-UK Newsletter 1 (4)
- CROSS-UK Newsletter 2 (6)
- CROSS-UK Newsletter 3 (2)
- CROSS-UK Newsletter 4 (4)
- CROSS-UK Newsletter 5 (3)
- CROSS-UK Newsletter 6 (1)
- CROSS-UK Newsletter 7 (3)
- CROSS-UK Newsletter 8 (3)
- CROSS-UK Newsletter 9 (2)
- CROSS-UK Newsletter 11 (2)
- CROSS-UK Newsletter 12 (1)
- CROSS-UK Newsletter 13 (3)
- CROSS-UK Newsletter 14 (1)
- CROSS-UK Newsletter 15 (1)
- CROSS-UK Newsletter 16 (2)
- CROSS-UK Newsletter 19 (2)
- CROSS-UK Newsletter 20 (3)
- CROSS-UK Newsletter 22 (2)
- CROSS-UK Newsletter 23 (8)
- CROSS-UK Newsletter 24 (3)
- CROSS-UK Newsletter 25 (3)
- CROSS-UK Newsletter 26 (2)
- CROSS-UK Newsletter 27 (1)
- CROSS-UK Newsletter 28 (2)
- CROSS-UK Newsletter 29 (2)
- CROSS-UK Newsletter 31 (3)
- CROSS-UK Newsletter 32 (7)
- CROSS-UK Newsletter 33 (5)
- CROSS-UK Newsletter 34 (2)
- CROSS-UK Newsletter 35 (2)
- CROSS-UK Newsletter 36 (3)
- CROSS-UK Newsletter 37 (4)
- CROSS-UK Newsletter 38 (1)
- CROSS-UK Newsletter 39 (2)
- CROSS-UK Newsletter 41 (6)
- CROSS-UK Newsletter 42 (5)
- CROSS-UK Newsletter 43 (4)
- CROSS-UK Newsletter 44 (4)
- CROSS-UK Newsletter 45 (3)
- CROSS-UK Newsletter 46 (1)
- CROSS-UK Newsletter 48 (2)
- CROSS-UK Newsletter 49 (3)
- CROSS-UK Newsletter 50 (5)
- CROSS-UK Newsletter 51 (2)
- CROSS-UK Newsletter 52 (4)
- CROSS-UK Newsletter 53 (2)
- CROSS-UK Newsletter 54 (6)
- CROSS-UK Newsletter 55 (4)
- CROSS-UK Newsletter 56 (6)
- CROSS-UK Newsletter 57 (5)
- CROSS-UK Newsletter 58 (4)
- CROSS-UK Newsletter 59 (5)
- CROSS-UK Newsletter 60 (5)
- CROSS-UK Newsletter 61 (3)
- CROSS-UK Newsletter 62 (7)
- CROSS-UK Newsletter 64 (4)
- CROSS-UK Newsletter 65 (5)
- CROSS-UK Newsletter 67 (5)
- CROSS-UK Newsletter 68 (4)
- CROSS-UK [sub-heading only] (162)
- CROSS-US Newsletter 1 (2)
- CROSS-US Newsletter 2 (3)
- CROSS-US [sub-heading only] (5)
- CROSS Feature Article (1)
- CROSS Newsletter (99)
- CROSS Safety Alert (7)
- CROSS Safety Report (293)
- CROSS Topic Paper (8)
- News [sub-heading only] (38)
- Safety information from CROSS [sub-heading only] (1)
- Safety information [sub-heading only] (1)
- Third party content (4)
- Third party content (2)
CROSS regions
Alteration of calculations on constructed loft conversion
A reporter says they were pressurised to adjust structural design calculations to pass a building control check.
1 July 2016
CROSS Safety Report
Report ID: 580
Region: CROSS-UK
Inadequate structural design of school extension
On review of a design for a school extension, a reporter noted several major issues including an almost total lack of vertical bracing throughout the extension.
1 October 2016
CROSS Safety Report
Report ID: 597
Region: CROSS-UK
Inadequate end bearings for transfer beams
Whilst advising a steel fabricator on tendering for a transfer structure steel frame, a reporter's firm noticed a serious design error with the bearing pressures at the supports of a transfer beam.
1 October 2017
CROSS Safety Report
Report ID: 644
Region: CROSS-UK
Response to report 614 on missing columns from drawings
A reporter shares their views on how to implement robust checking systems for Building Information Modelling (BIM) models.
1 January 2020
CROSS Safety Report
Report ID: 645
Region: CROSS-UK
Tower crane foundation design error
Whilst carrying out an independent design check on a tower crane foundation design, a reporter discovered that the piles used on site did not have the required tension capacity.
1 July 2018
CROSS Safety Report
Report ID: 662
Region: CROSS-UK
Use of proprietary element beyond stated values
After the construction of a 6m high lighting frame, the contractor noticed that the frame was both twisting and deflecting excessively under wind loading.
1 April 2018
CROSS Safety Report
Report ID: 667
Region: CROSS-UK
Collapse of unsupported deep trench excavation
A worker was trapped within a partially collapsed excavation which was unsupported and not suitably benched.
1 October 2019
CROSS Safety Report
Report ID: 675
Region: CROSS-UK
Architect conducts structural design of sway frame for domestic project
A reporter looked at a project recently where the drawings had been produced by the architect, including a structural design.
1 April 2018
CROSS Safety Report
Report ID: 678
Region: CROSS-UK
Concern about foundations to telecoms masts
Concerns are raised about a potential safety problem with the design and construction of ‘root’ foundations for telecom poles.
1 January 2018
CROSS Safety Report
Report ID: 690
Region: CROSS-UK
Casting, transporting and installing precast concrete kerbs
A reporter shares their experience of how collaborative engineering thinking involving several parties enabled a design solution to be found that could be constructed safely.
1 October 2018
CROSS Safety Report
Report ID: 778
Region: CROSS-UK