Safety information search results
Filter your results
Building or structure type
- Bridges (25)
- Buildings
(193)
- Agricultural buildings (8)
- Commercial (19)
- Consequence Class 3 buildings (3)
- Education, science & art buildings (11)
- Health care (2)
- Higher-risk buildings (3)
- Industrial buildings (5)
- Laboratory buildings (1)
- Nuclear & energy buildings (1)
- Public, religious & civic buildings (7)
- Recreational buildings (6)
- Residential (51)
- Stadiums (2)
- Storage buildings (6)
- Tall buildings (12)
- Theatres & other entertainment buildings (5)
- Transport buildings (2)
- Buried pipes & culverts (2)
- Car parks (6)
- Flats & apartments (10)
- Floating structures (1)
- Freestanding walls (2)
- Hotels & hostels (1)
- Houses (21)
- Marine structures (2)
- Masts & towers (7)
- Offshore structures (1)
- Railways (4)
- Reservoirs & dams (2)
- Retaining structures (14)
- Roads (5)
- Sewers (2)
- Temporary structures (14)
- Tunnels (1)
Materials
Project or lifecycle stage
Design
- BIM (5)
- Computational design (12)
- Design: quality management (59)
- Design calculations (74)
- Design conceptualisation (26)
- Design detailing (83)
- Design drawings (28)
- Design loads (73)
- Design software (33)
- Dynamics (6)
- Fire safety design (13)
- Resilience (14)
- Robustness (34)
- Structural design (98)
- Sustainability (4)
Codes, standards & regulations
Fire incident response
Project type
- Alteration & conversion project (21)
- Assessment project [sub-heading only] (7)
- Conservation & restoration project (2)
- Construction project [sub-heading only] (103)
- Demolition project (1)
- Excavation (5)
- Extension project (13)
- Groundworks project (1)
- Maintenance project (3)
- New build (48)
- Refurbishment (15)
- Remediation project (11)
- Repair project (6)
- Strengthening project (3)
- Structural assessment (15)
- Underpinning project (2)
Construction period
Method of construction
Elements & systems
- Arch (2)
- Balconies (4)
- Balustrades (9)
- Basements (7)
- Beams (44)
- Bracing (12)
- Canopies (1)
- Ceilings (7)
- Cladding (20)
- Columns (26)
- Fasteners & connections (70)
- Fences (1)
- Fire protection (8)
- Foundations (16)
- Insulation (8)
- Light gauge steel framing (6)
- Padstones (2)
- Parapets (4)
- PV panels (3)
- Roofs (43)
- Sandwich panels (2)
- Shear walls (2)
- Signs (1)
- Slabs (26)
- Trusses (9)
- Walls (40)
- Wall ties (4)
Plant & equipment
Utilities
Safety reporting
Organisations
- CROSS-AUS [sub-heading only] (7)
- CROSS-UK [sub-heading only]
(29)
- Building Control Northern Ireland (2)
- Building Safety Regulator (BSR) (1)
- Environment Agency (1)
- Fire and Rescue Service (FRS) (3)
- Health and Safety Executive (HSE) (8)
- Local Authority Building Control (LABC) (12)
- Local Authority Building Standards Scotland (LABSS) (2)
- Scottish Environment Protection Agency (SEPA) (1)
Business practice
Content type
- CROSS-AUS Newsletter 1 (1)
- CROSS-AUS Newsletter 2 (2)
- CROSS-AUS Newsletter 3 (4)
- CROSS-AUS Newsletter 4 (3)
- CROSS-AUS Newsletter 5 (2)
- CROSS-AUS [sub-heading only] (10)
- CROSS-UK Newsletter 1 (4)
- CROSS-UK Newsletter 2 (6)
- CROSS-UK Newsletter 3 (2)
- CROSS-UK Newsletter 4 (4)
- CROSS-UK Newsletter 5 (3)
- CROSS-UK Newsletter 6 (1)
- CROSS-UK Newsletter 7 (3)
- CROSS-UK Newsletter 8 (3)
- CROSS-UK Newsletter 9 (2)
- CROSS-UK Newsletter 11 (2)
- CROSS-UK Newsletter 12 (1)
- CROSS-UK Newsletter 13 (3)
- CROSS-UK Newsletter 14 (1)
- CROSS-UK Newsletter 15 (1)
- CROSS-UK Newsletter 16 (2)
- CROSS-UK Newsletter 19 (2)
- CROSS-UK Newsletter 20 (3)
- CROSS-UK Newsletter 22 (2)
- CROSS-UK Newsletter 23 (8)
- CROSS-UK Newsletter 24 (3)
- CROSS-UK Newsletter 25 (3)
- CROSS-UK Newsletter 26 (2)
- CROSS-UK Newsletter 27 (1)
- CROSS-UK Newsletter 28 (2)
- CROSS-UK Newsletter 29 (2)
- CROSS-UK Newsletter 31 (3)
- CROSS-UK Newsletter 32 (7)
- CROSS-UK Newsletter 33 (5)
- CROSS-UK Newsletter 34 (2)
- CROSS-UK Newsletter 35 (2)
- CROSS-UK Newsletter 36 (3)
- CROSS-UK Newsletter 37 (4)
- CROSS-UK Newsletter 38 (1)
- CROSS-UK Newsletter 39 (2)
- CROSS-UK Newsletter 41 (6)
- CROSS-UK Newsletter 42 (5)
- CROSS-UK Newsletter 43 (4)
- CROSS-UK Newsletter 44 (4)
- CROSS-UK Newsletter 45 (3)
- CROSS-UK Newsletter 46 (1)
- CROSS-UK Newsletter 48 (2)
- CROSS-UK Newsletter 49 (3)
- CROSS-UK Newsletter 50 (5)
- CROSS-UK Newsletter 51 (2)
- CROSS-UK Newsletter 52 (4)
- CROSS-UK Newsletter 53 (2)
- CROSS-UK Newsletter 54 (6)
- CROSS-UK Newsletter 55 (4)
- CROSS-UK Newsletter 56 (6)
- CROSS-UK Newsletter 57 (5)
- CROSS-UK Newsletter 58 (4)
- CROSS-UK Newsletter 59 (5)
- CROSS-UK Newsletter 60 (5)
- CROSS-UK Newsletter 61 (3)
- CROSS-UK Newsletter 62 (6)
- CROSS-UK Newsletter 64 (4)
- CROSS-UK Newsletter 65 (5)
- CROSS-UK Newsletter 67 (5)
- CROSS-UK Newsletter 68 (4)
- CROSS-UK [sub-heading only] (162)
- CROSS-US Newsletter 1 (2)
- CROSS-US Newsletter 2 (3)
- CROSS-US [sub-heading only] (5)
- CROSS Newsletter (99)
- (-) CROSS Safety Report (293)
- News [sub-heading only] (38)
- Safety information from CROSS [sub-heading only] (1)
- Safety information [sub-heading only] (1)
CROSS regions
Light gauge steel fabrication
Referring to Report AUS-4, Light steel truss issues, this reporter has concerns about the low ductility of the high tensile steel, in particular with respect to connection design and capacity.
1 August 2020
CROSS Safety Report
Report ID: 957
Region: CROSS-AUS
Roof collapse at primary school
Blocked drainage outlets likely lead to the build-up of water on a school roof which collapsed.
1 July 2020
CROSS Safety Report
Report ID: 958
Region: CROSS-UK
Failure of existing long-span wood roof truss following installation of new roof-top HVAC units
Failure of an existing long-span wood roof truss following installation of new roof-top Heating, Ventilating, and Air Conditioning (HVAC) units offers lessons in the special challenges of renovations to existing buildings.
1 September 2020
CROSS Safety Report
Report ID: 949
Region: CROSS-US
Workmanship in domestic buildings
A reporter has raised concerns after discovering a steel beam on site had its web cut away at the support without approval from the design engineer.
14 October 2020
CROSS Safety Report
Report ID: 971
Region: CROSS-UK
GFRP reinforcement in concrete structures
A correspondent has become aware of work being undertaken in the field of glass fibre reinforced polymer (GFRP) reinforcement as a substitute for steel rebar in concrete structures and is deeply concerned by what they have observed.
1 August 2020
CROSS Safety Report
Report ID: 939
Region: CROSS-AUS
Execution not matching design assumptions
This report highlights how the connection of steel columns to twin beams acting as a transfer beam was overlooked and created an eccentric loading condition.
14 October 2020
CROSS Safety Report
Report ID: 968
Region: CROSS-UK
Incorrectly installed tension control bolts could have led to serious consequences
A reporter finds incorrectly installed system HRC preload bolt assemblies, better known as tension control bolts, during a site inspection of a new highway bridge over a railway. The incorrectly fitted bolts could have had major structural implications, and led to other safety risks, if the installation error had not been spotted.
24 May 2023
CROSS Safety Report
Report ID: 1196
Region: CROSS-UK
Bottom-chord bracing for metal plate-connected wood trusses used in light-commercial applications
Concerns regarding metal plate-connected wood trusses in light-commercial construction when subject to net uplift.
1 September 2020
CROSS Safety Report
Report ID: 985
Region: CROSS-US
Fire risks in multi-storey car parks
A reporter is concerned by the reluctance of the industry to voluntarily take on board and proactively react to the lessons learnt from the fire at the Echo Arena car park in Liverpool.
14 October 2020
CROSS Safety Report
Report ID: 940
Region: CROSS-UK
Collapse of a reinforcing cage
The reinforcing cage to a blade pier for an overpass bridge collapsed without warning when nearing completion.
1 August 2020
CROSS Safety Report
Report ID: 941
Region: CROSS-AUS