Safety information search results
Filter your results
Building or structure type
Materials
Project or lifecycle stage
Design
- BIM (1)
- Computational design (2)
- Design: quality management (7)
- Design calculations (7)
- Design conceptualisation (2)
- Design detailing (10)
- Design drawings (5)
- Design loads (17)
- Design software (3)
- Dynamics (3)
- Fire safety design (5)
- Resilience (1)
- Robustness (3)
- Structural design (21)
- Sustainability (3)
Fire incident response
Method of construction
Structural form
Elements & systems
- Balconies (1)
- Balustrades (2)
- Beams (5)
- Cables (1)
- Canopies (1)
- Ceilings (2)
- Cladding (2)
- Columns (5)
- Fasteners & connections (11)
- Fire protection (2)
- Foundations (2)
- Light gauge steel framing (4)
- Parapets (1)
- PV panels (2)
- Roofs (8)
- Sandwich panels (1)
- Signs (2)
- Slabs (8)
- Trusses (1)
- Walls (9)
- Wall ties (1)
Plant & equipment
Utilities
Safety reporting
Project delivery methods
Business practice
Public incidents
Locations
Content type
- CROSS-AUS Newsletter 2 (6)
- CROSS-AUS Newsletter 3 (6)
- CROSS-AUS Newsletter 4 (6)
- CROSS-AUS Newsletter 5 (4)
- CROSS-AUS Newsletter 8 (2)
- CROSS-AUS [sub-heading only] (17)
- CROSS-UK Newsletter 4 (1)
- CROSS-UK Newsletter 58 (1)
- CROSS-UK [sub-heading only] (1)
- CROSS Safety Alert (22)
- CROSS Safety Report (45)
- CROSS Theme Page (2)
- Safety information from CROSS [sub-heading only] (1)
- Safety information [sub-heading only] (4)
- Third party content (6)
- Third party content (2)
CROSS regions
Defects found in precast (prefabricated) concrete façades
The reporter found several issues when inspecting or reviewing buildings with precast concrete façades, particularly on older buildings, due to a lack of attention to durability and poor workmanship.
30 March 2023
CROSS Safety Report
Report ID: 995
Region: CROSS-AUS
Essential consideration of ‘soft hazards’ on civil and building engineering projects
A check-list for all those engaged in structural or fire engineering design.
7 December 2022
Third party content
Punching shear in concrete slabs at perimeter columns
A reporter raises concerns about the underestimation of bending moments in perimeter columns when assessing punching shear in adjacent concrete slabs. Punching shear failures can be brittle and catastrophic. Designers need to include the appropriate ultimate moment in the design actions.
14 October 2022
CROSS Safety Report
Report ID: 1122
Region: CROSS-AUS
Condition assessments of exposed lightweight canopy roofs
Defects in lightweight canopy roofs, using underslung roofing sheets in many cases.
14 October 2022
CROSS Safety Report
Report ID: 1084
Region: CROSS-AUS
Production of as-constructed drawings
The reporter is concerned about who should be responsible for producing accurate “as-constructed” drawings. The reporter’s experience is that the as-constructed drawings are typically likely to be incomplete and contain errors.
14 October 2022
CROSS Safety Report
Report ID: 1056
Region: CROSS-AUS
Construction products- fire test certificates
A reporter has notified CROSS-AUS regarding the potentially inappropriate use of regulatory/compliance fire test methods on certain products. This has led, they say, to the circulation of inaccurate test certificates in the market and possibly the use of these products on buildings where they may not be suitable.
2 August 2022
CROSS Safety Report
Report ID: 1060
Region: CROSS-AUS
Modelling of structures
The reporter is concerned that some structural engineers assume without adequate verification that their computer modelling is correct and accurate; that they do not understand the limitations or basis for their modelling; or that the model chosen may not be appropriate for that structure.
2 August 2022
CROSS Safety Report
Report ID: 994
Region: CROSS-AUS
Continuously threaded reinforcing bar
This report highlights the difficulty of inspecting continuously threaded reinforcing bars to ensure that they have been adequately inserted into the cast-in ferrules.
2 August 2022
CROSS Safety Report
Report ID: 1074
Region: CROSS-AUS
Site testing of post-installed fasteners in concrete
This report describes a situation where site testing of post-installed fasteners in concrete was undertaken by a contractor as an alternative to adopting the design data from the manufacturer in an attempt to justify an increased design capacity for the fasteners.
2 August 2022
CROSS Safety Report
Report ID: 1091
Region: CROSS-AUS
Safety of structures in the climate emergency
In the current climate emergency and the race to achieve zero emissions, we must ensure our structures remain safe as we develop and implement any climate-motivated innovation or change of approach.
CROSS Theme Page
Region: CROSS-UK, CROSS-AUS, CROSS-US