Retaining wall collapses onto rail track

Report ID: 775 Published: 1 June 2022 Region: CROSS-UK


Overview

A retaining wall failed and collapsed onto a railway track.

Key Learning Outcomes

For asset owners and managers:

  • Regular inspections and maintenance can help keep a structure safe before it deteriorates requiring costly repairs or fails

  • Inspections should be carried out by suitably qualified and experienced personnel 

Full Report

Find out more about the Full Report

Our secure and confidential safety reporting system gives professionals the opportunity to share their experiences to help others. If you would like to know more, please visit the reporting to CROSS-US page.

A train driver reporter that stones were falling from an inclined retaining wall onto a rail track. The wall failed directly in front of a piled foundation for an electricity mast which was installed within the past 18 months. The night before the wall failed there was an intense period of rainfall which followed a sustained period where temperatures were below freezing.

Expert Panel Comments

Find out more about the Expert Panel

An Expert Panel comment on the reports we receive. They use their experience to help you understand what can be learned from the reports. If you would like to know more, please visit the CROSS-US Expert Panel page.

There are no Expert Panel comments on this report. The Expert Panels are only asked to comment on selected reports. These are normally reports where there is an opportunity for them to help you understand what can be learned from the report.

Submit a report

Your report will make a difference. It will help to create positive change and improve safety.

Our secure and confidential safety reporting system gives professionals the opportunity to share their experiences to help others.