Safety information search results
Filter your results
Building or structure type
Materials
Project or lifecycle stage
Design
- BIM (1)
- Computational design (2)
- Design: quality management (7)
- Design calculations (7)
- Design conceptualisation (2)
- Design detailing (10)
- Design drawings (5)
- Design loads (17)
- Design software (3)
- Dynamics (3)
- Fire safety design (5)
- Resilience (1)
- Robustness (3)
- Structural design (21)
- Sustainability (3)
Fire incident response
Method of construction
Structural form
Elements & systems
- Balconies (1)
- Balustrades (2)
- Beams (5)
- Cables (1)
- Canopies (1)
- Ceilings (2)
- Cladding (2)
- Columns (5)
- Fasteners & connections (11)
- Fire protection (2)
- Foundations (2)
- Light gauge steel framing (4)
- Parapets (1)
- PV panels (2)
- Roofs (8)
- Sandwich panels (1)
- Signs (2)
- Slabs (8)
- Trusses (1)
- Walls (9)
- Wall ties (1)
Plant & equipment
Utilities
Safety reporting
Project delivery methods
Business practice
Public incidents
Locations
Content type
- CROSS-AUS Newsletter 2 (6)
- CROSS-AUS Newsletter 3 (6)
- CROSS-AUS Newsletter 4 (6)
- CROSS-AUS Newsletter 5 (4)
- CROSS-AUS Newsletter 8 (2)
- CROSS-AUS [sub-heading only] (17)
- CROSS-UK Newsletter 4 (1)
- CROSS-UK Newsletter 58 (1)
- CROSS-UK [sub-heading only] (1)
- CROSS Safety Alert (22)
- CROSS Safety Report (44)
- CROSS Theme Page (3)
- Safety information from CROSS [sub-heading only] (1)
- Safety information [sub-heading only] (4)
- Third party content (6)
- Third party content (2)
CROSS regions
Light gauge steel fabrication
Referring to Report AUS-4, Light steel truss issues, this reporter has concerns about the low ductility of the high tensile steel, in particular with respect to connection design and capacity.
1 August 2020
CROSS Safety Report
Report ID: 957
Region: CROSS-AUS
Overloading metal decking in temporary state
During construction of steel structures with composite metal decking floors, a reporter has observed numerous occasions when the metal decking was close to being overloaded.
1 August 2020
CROSS Safety Report
Report ID: 919
Region: CROSS-AUS
Failure of RAAC planks in schools
A reporter was asked to investigate a reinforced autoclaved aerated concrete (RAAC) roof which had collapsed in a school.
1 April 2020
CROSS Safety Report
Report ID: 908
Region: CROSS-UK, CROSS-AUS, CROSS-US
GFRP reinforcement in concrete structures
A correspondent has become aware of work being undertaken in the field of glass fibre reinforced polymer (GFRP) reinforcement as a substitute for steel rebar in concrete structures and is deeply concerned by what they have observed.
1 August 2020
CROSS Safety Report
Report ID: 939
Region: CROSS-AUS
Collapse of a reinforcing cage
The reinforcing cage to a blade pier for an overpass bridge collapsed without warning when nearing completion.
1 August 2020
CROSS Safety Report
Report ID: 941
Region: CROSS-AUS