Safety information search results
Filter your results
Building or structure type
- Bridges (18)
- Buildings
(143)
- Agricultural buildings (4)
- Car parks (7)
- Commercial (11)
- Consequence Class 3 buildings (3)
- Education, science & art buildings (5)
- Higher-risk buildings (1)
- Industrial buildings (3)
- LPS buildings (3)
- Public, religious & civic buildings (2)
- Residential (42)
- Stadiums (2)
- Storage buildings (3)
- Tall buildings (8)
- Theatres & other entertainment buildings (1)
- Buried pipes & culverts (1)
- Marine structures (1)
- Masts & towers (5)
- Offshore structures (1)
- Railways (5)
- Reservoirs & dams (1)
- Retaining structures (9)
- Roads (5)
- Temporary structures (19)
- Tunnels (1)
Materials
Project or lifecycle stage
Design
- BIM (2)
- Computational design (2)
- Design: quality management (36)
- Design calculations (38)
- Design conceptualisation (2)
- Design detailing (38)
- Design drawings (13)
- Design loads (35)
- Design software (19)
- Dynamics (3)
- Fire safety design (5)
- Resilience (8)
- Robustness (17)
- Structural design (49)
- Sustainability (4)
Fire incident response
Project type
- Alteration & conversion project (14)
- Assessment project [sub-heading only] (8)
- Conservation & restoration project (1)
- Construction project [sub-heading only] (98)
- Demolition project (6)
- Excavation (7)
- Extension project (10)
- Fire safety assessment (1)
- Maintenance project (1)
- New build (45)
- Refurbishment (3)
- Remediation project (4)
- Strengthening project (6)
- Structural assessment (7)
- Underpinning project (3)
Method of construction
Elements & systems
- Arch (3)
- Balconies (4)
- Balustrades (6)
- Basements (6)
- Beams (38)
- Bracing (9)
- Cables (1)
- Canopies (2)
- Ceilings (2)
- Cladding (5)
- Columns (16)
- Fasteners & connections (48)
- Fire protection (4)
- Foundations (16)
- Insulation (1)
- Light gauge steel framing (1)
- Lintels (1)
- Padstones (1)
- Parapets (3)
- Roofs (21)
- Shear walls (1)
- Signs (2)
- Slabs (15)
- Trusses (2)
- Wall head restraints (1)
- Walls (32)
- Wall ties (4)
Plant & equipment
Utilities
Safety reporting
Project delivery methods
Business practice
Locations
Content type
- CROSS-AUS Newsletter 1 (1)
- CROSS-AUS [sub-heading only] (1)
- CROSS-UK Newsletter 1 (8)
- CROSS-UK Newsletter 2 (4)
- CROSS-UK Newsletter 3 (4)
- CROSS-UK Newsletter 4 (3)
- CROSS-UK Newsletter 5 (4)
- CROSS-UK Newsletter 6 (3)
- CROSS-UK Newsletter 7 (5)
- CROSS-UK Newsletter 8 (2)
- CROSS-UK Newsletter 9 (1)
- CROSS-UK Newsletter 10 (1)
- CROSS-UK Newsletter 11 (2)
- CROSS-UK Newsletter 12 (2)
- CROSS-UK Newsletter 13 (5)
- CROSS-UK Newsletter 14 (3)
- CROSS-UK Newsletter 16 (4)
- CROSS-UK Newsletter 17 (2)
- CROSS-UK Newsletter 18 (1)
- CROSS-UK Newsletter 19 (3)
- CROSS-UK Newsletter 20 (2)
- CROSS-UK Newsletter 21 (4)
- CROSS-UK Newsletter 22 (3)
- CROSS-UK Newsletter 23 (3)
- CROSS-UK Newsletter 24 (2)
- CROSS-UK Newsletter 25 (2)
- CROSS-UK Newsletter 26 (3)
- CROSS-UK Newsletter 27 (2)
- CROSS-UK Newsletter 28 (3)
- CROSS-UK Newsletter 29 (5)
- CROSS-UK Newsletter 30 (5)
- CROSS-UK Newsletter 31 (3)
- CROSS-UK Newsletter 32 (5)
- CROSS-UK Newsletter 33 (5)
- CROSS-UK Newsletter 34 (1)
- CROSS-UK Newsletter 35 (2)
- CROSS-UK Newsletter 36 (2)
- CROSS-UK Newsletter 37 (4)
- CROSS-UK Newsletter 38 (2)
- CROSS-UK Newsletter 39 (4)
- CROSS-UK Newsletter 40 (2)
- CROSS-UK Newsletter 41 (5)
- CROSS-UK Newsletter 42 (7)
- CROSS-UK Newsletter 43 (2)
- CROSS-UK Newsletter 44 (3)
- CROSS-UK Newsletter 45 (6)
- CROSS-UK Newsletter 46 (3)
- CROSS-UK Newsletter 47 (4)
- CROSS-UK Newsletter 48 (3)
- CROSS-UK Newsletter 49 (6)
- CROSS-UK Newsletter 50 (6)
- CROSS-UK Newsletter 51 (1)
- CROSS-UK Newsletter 52 (3)
- CROSS-UK Newsletter 53 (4)
- CROSS-UK Newsletter 54 (8)
- CROSS-UK Newsletter 55 (4)
- CROSS-UK Newsletter 56 (2)
- CROSS-UK Newsletter 57 (5)
- CROSS-UK Newsletter 58 (3)
- CROSS-UK Newsletter 59 (5)
- CROSS-UK Newsletter 60 (3)
- CROSS-UK Newsletter 67 (1)
- CROSS-UK [sub-heading only] (196)
- CROSS Newsletter (110)
- CROSS Safety Report (252)
- News [sub-heading only] (39)
- Safety information from CROSS [sub-heading only] (1)
CROSS regions
CE marking scheme for structural steelwork
Concern has been expressed about the way in which the CE marking scheme for structural steelwork will be monitored, enforced and policed in the UK, since the use of CE marking is only voluntary here (but compulsory in mainland Europe).
1 April 2007
CROSS Safety Report
Report ID: 70
Region: CROSS-UK
Low pitched metal sheet roofs
A reporter is concerned about low pitch metal sheet roofing attached to trussed rafters.
1 April 2007
CROSS Safety Report
Report ID: 66
Region: CROSS-UK
Local authorities and approved inspectors
A reporter is very concerned that the system of building control where there is competition between local authorities and approved inspectors, has produced a situation where the level of independent inspection has fallen dramatically.
1 July 2007
CROSS Safety Report
Report ID: 67
Region: CROSS-UK
Balustrades in public buildings
A reporter had a concern regarding a timber balustrade in a showroom.
1 February 2007
CROSS Safety Report
Report ID: 61
Region: CROSS-UK
Timber truss
The reporter has been dealing with an application where the engineer involved discovered proprietary timber girder trusses with some glued joints that have come loose.
1 February 2007
CROSS Safety Report
Report ID: 62
Region: CROSS-UK
Building Regulations submission for a small house
A reporter who is a small builder shares their experience on inadequate design calculations they received for a small house.
1 January 2008
CROSS Safety Report
Report ID: 91
Region: CROSS-UK
Collapse of a wall during construction
An internal corridor wall collapsed in a school under construction.
1 April 2008
CROSS Safety Report
Report ID: 99
Region: CROSS-UK
Unsafe street lighting columns
A reporter raises concerns over the poor construction of street light poles and advertisement boards.
1 April 2009
CROSS Safety Report
Report ID: 98
Region: CROSS-UK
Incorrect use of timber joist hanger
A reporter has become aware of another collapse resulting from the incorrect use of proprietary timber joist hangers in housing construction.
1 January 2008
CROSS Safety Report
Report ID: 95
Region: CROSS-UK
Proper design and use of cold rolled steel frames
A reporter has been designing structures in cold rolled steel for approximately twenty years, mainly portal frame buildings, and some concerns.
1 January 2008
CROSS Safety Report
Report ID: 93
Region: CROSS-UK