Safety information search results
Filter your results
Building or structure type
- Bridges (5)
- Buildings
(78)
- Agricultural buildings (6)
- Commercial (6)
- Education, science & art buildings (6)
- Health care (1)
- Industrial buildings (3)
- Public, religious & civic buildings (2)
- Recreational buildings (2)
- Residential (16)
- Stadiums (2)
- Storage buildings (6)
- Tall buildings (9)
- Theatres & other entertainment buildings (1)
- Transport buildings (3)
- Buried pipes & culverts (3)
- Car parks (5)
- Flats & apartments (3)
- Freestanding walls (2)
- Houses (7)
- Railways (2)
- Reservoirs & dams (1)
- Retaining structures (6)
- Roads (3)
- Sewers (2)
- Temporary structures (10)
- Tunnels (1)
Materials
Project or lifecycle stage
Design
Codes, standards & regulations
Fire incident response
Project type
- Alteration & conversion project (1)
- Assessment project [sub-heading only] (1)
- Construction project [sub-heading only] (24)
- Excavation (2)
- Extension project (2)
- Groundworks project (2)
- Maintenance project (1)
- New build (7)
- Refurbishment (2)
- Remediation project (3)
- Repair project (2)
- Strengthening project (2)
- Structural assessment (2)
Method of construction
Structural form
Elements & systems
- ACM cladding (1)
- Arch (1)
- Balconies (2)
- Balustrades (4)
- Beams (4)
- Bracing (2)
- Cables (1)
- Canopies (1)
- Ceilings (4)
- Cladding (12)
- Columns (4)
- Fasteners & connections (29)
- Foundations (3)
- Insulation (1)
- Light gauge steel framing (3)
- Padstones (1)
- Parapets (7)
- PV panels (1)
- Roofs (29)
- Sandwich panels (1)
- Shear walls (1)
- Signs (2)
- Slabs (3)
- Trusses (3)
- Wall head restraints (2)
- Walls (17)
- Wall ties (4)
Plant & equipment
Weather & natural hazards
Utilities
Safety reporting
Organisations
Project delivery methods
Business practice
Public incidents
Content type
- CROSS-AUS Newsletter 1 (1)
- CROSS-AUS Newsletter 2 (3)
- CROSS-AUS Newsletter 3 (1)
- CROSS-AUS Newsletter 4 (2)
- CROSS-AUS Newsletter 5 (2)
- CROSS-AUS Newsletter 8 (1)
- CROSS-AUS [sub-heading only] (6)
- CROSS-UK Newsletter 1 (2)
- CROSS-UK Newsletter 3 (1)
- CROSS-UK Newsletter 4 (1)
- CROSS-UK Newsletter 5 (1)
- CROSS-UK Newsletter 6 (2)
- CROSS-UK Newsletter 8 (3)
- CROSS-UK Newsletter 10 (1)
- CROSS-UK Newsletter 11 (1)
- CROSS-UK Newsletter 12 (2)
- CROSS-UK Newsletter 13 (2)
- CROSS-UK Newsletter 14 (1)
- CROSS-UK Newsletter 15 (1)
- CROSS-UK Newsletter 17 (1)
- CROSS-UK Newsletter 20 (1)
- CROSS-UK Newsletter 23 (7)
- CROSS-UK Newsletter 25 (2)
- CROSS-UK Newsletter 26 (1)
- CROSS-UK Newsletter 33 (1)
- CROSS-UK Newsletter 34 (1)
- CROSS-UK Newsletter 35 (1)
- CROSS-UK Newsletter 36 (4)
- CROSS-UK Newsletter 37 (3)
- CROSS-UK Newsletter 40 (1)
- CROSS-UK Newsletter 41 (1)
- CROSS-UK Newsletter 43 (1)
- CROSS-UK Newsletter 44 (2)
- CROSS-UK Newsletter 45 (1)
- CROSS-UK Newsletter 46 (1)
- CROSS-UK Newsletter 47 (1)
- CROSS-UK Newsletter 50 (1)
- CROSS-UK Newsletter 51 (1)
- CROSS-UK Newsletter 52 (1)
- CROSS-UK Newsletter 54 (2)
- CROSS-UK Newsletter 56 (2)
- CROSS-UK Newsletter 58 (1)
- CROSS-UK Newsletter 59 (1)
- CROSS-UK Newsletter 60 (1)
- CROSS-UK Newsletter 65 (1)
- CROSS-UK Newsletter 67 (1)
- CROSS-UK Newsletter 68 (2)
- CROSS-UK [sub-heading only] (55)
- CROSS-US Newsletter 1 (4)
- CROSS-US Newsletter 2 (3)
- CROSS-US Newsletter 3 (1)
- CROSS-US [sub-heading only] (6)
- CROSS Newsletter (27)
- CROSS Safety Alert (9)
- CROSS Safety Report (104)
- CROSS Topic Paper (1)
- News [sub-heading only] (7)
- Safety information from CROSS [sub-heading only] (1)
- Safety information [sub-heading only] (1)
CROSS regions
Suspended granite ceiling collapse
This report is in relation to the selection of fixings for a suspended ceiling of granite which collapsed in the entrance area of a new office building due to failures of the fixings.
1 January 2010
CROSS Safety Report
Report ID: 148
Region: CROSS-UK
School fascia board failure
A section of pressed steel gutter and plywood fascia board at a school collapsed during or after a heavy rainstorm.
1 April 2009
CROSS Safety Report
Report ID: 137
Region: CROSS-UK
Brick bridge collapse
A historic bridge collapsed minutes after workers fled to safety.
1 October 2008
CROSS Safety Report
Report ID: 138
Region: CROSS-UK
Underpass ceiling collapse
Six months after completion, the ceiling structure to the soffit of an underpass collapsed.
1 July 2009
CROSS Safety Report
Report ID: 140
Region: CROSS-UK
Thermal effects on long span concrete car park beams
A reporter describes how long span precast hollow core units in a car park started to bow upwards due to thermal effects.
1 October 2010
CROSS Safety Report
Report ID: 173
Region: CROSS-UK
Loading from solar panels
A reporter inspected a roof to discover that the structure was already overloaded with the self weight of the roof covering without the addition of solar panels.
1 January 2012
CROSS Safety Report
Report ID: 280
Region: CROSS-UK
Freezing splits galvanised SHS columns
Concerns were raised after several square hollow section members split vertically on a partially complete construction site.
1 April 2012
CROSS Safety Report
Report ID: 253
Region: CROSS-UK
PV solar panels
This reporter queries whether enough attention is being paid to the loads applied by PV (Photo Voltaic) solar panels added to roofs.
1 January 2012
CROSS Safety Report
Report ID: 266
Region: CROSS-UK
Snow loading in Scotland - summary of reports
There were heavy snowfalls over the entire United Kingdom in the winters of 2009/2010 and 2010/2011 and CROSS received a number of reports, mostly from Scotland where a significant number of buildings suffered roof collapses.
1 July 2011
CROSS Safety Report
Report ID: 264
Region: CROSS-UK
Multi-storey car parks demolished due to structural defects
A reporter shares their experience on two instances where their firm has prepared reports and carried out numerical assessments of city centre car parks that have led to the car parks being demolished.
1 April 2012
CROSS Safety Report
Report ID: 267
Region: CROSS-UK