Safety information search results
Filter your results
Building or structure type
- Bridges (18)
- Buildings
(143)
- Agricultural buildings (4)
- Car parks (7)
- Commercial (11)
- Consequence Class 3 buildings (3)
- Education, science & art buildings (5)
- Higher-risk buildings (1)
- Industrial buildings (3)
- LPS buildings (3)
- Public, religious & civic buildings (2)
- Residential (42)
- Stadiums (2)
- Storage buildings (3)
- Tall buildings (8)
- Theatres & other entertainment buildings (1)
- Buried pipes & culverts (1)
- Marine structures (1)
- Masts & towers (5)
- Offshore structures (1)
- Railways (5)
- Reservoirs & dams (1)
- Retaining structures (9)
- Roads (5)
- Temporary structures (19)
- Tunnels (1)
Materials
Project or lifecycle stage
Design
- BIM (2)
- Computational design (2)
- Design: quality management (36)
- Design calculations (38)
- Design conceptualisation (2)
- Design detailing (38)
- Design drawings (13)
- Design loads (35)
- Design software (19)
- Dynamics (3)
- Fire safety design (5)
- Resilience (8)
- Robustness (17)
- Structural design (49)
- Sustainability (4)
Fire incident response
Project type
- Alteration & conversion project (14)
- Assessment project [sub-heading only] (8)
- Conservation & restoration project (1)
- Construction project [sub-heading only] (98)
- Demolition project (6)
- Excavation (7)
- Extension project (10)
- Fire safety assessment (1)
- Maintenance project (1)
- New build (45)
- Refurbishment (3)
- Remediation project (4)
- Strengthening project (6)
- Structural assessment (7)
- Underpinning project (3)
Method of construction
Elements & systems
- Arch (3)
- Balconies (4)
- Balustrades (6)
- Basements (6)
- Beams (38)
- Bracing (9)
- Cables (1)
- Canopies (2)
- Ceilings (2)
- Cladding (5)
- Columns (16)
- Fasteners & connections (48)
- Fire protection (4)
- Foundations (16)
- Insulation (1)
- Light gauge steel framing (1)
- Lintels (1)
- Padstones (1)
- Parapets (3)
- Roofs (21)
- Shear walls (1)
- Signs (2)
- Slabs (15)
- Trusses (2)
- Wall head restraints (1)
- Walls (32)
- Wall ties (4)
Plant & equipment
Utilities
Safety reporting
Project delivery methods
Business practice
Locations
Content type
- CROSS-AUS Newsletter 1 (1)
- CROSS-AUS [sub-heading only] (1)
- CROSS-UK Newsletter 1 (8)
- CROSS-UK Newsletter 2 (4)
- CROSS-UK Newsletter 3 (4)
- CROSS-UK Newsletter 4 (3)
- CROSS-UK Newsletter 5 (4)
- CROSS-UK Newsletter 6 (3)
- CROSS-UK Newsletter 7 (5)
- CROSS-UK Newsletter 8 (2)
- CROSS-UK Newsletter 9 (1)
- CROSS-UK Newsletter 10 (1)
- CROSS-UK Newsletter 11 (2)
- CROSS-UK Newsletter 12 (2)
- CROSS-UK Newsletter 13 (5)
- CROSS-UK Newsletter 14 (3)
- CROSS-UK Newsletter 16 (4)
- CROSS-UK Newsletter 17 (2)
- CROSS-UK Newsletter 18 (1)
- CROSS-UK Newsletter 19 (3)
- CROSS-UK Newsletter 20 (2)
- CROSS-UK Newsletter 21 (4)
- CROSS-UK Newsletter 22 (3)
- CROSS-UK Newsletter 23 (3)
- CROSS-UK Newsletter 24 (2)
- CROSS-UK Newsletter 25 (2)
- CROSS-UK Newsletter 26 (3)
- CROSS-UK Newsletter 27 (2)
- CROSS-UK Newsletter 28 (3)
- CROSS-UK Newsletter 29 (5)
- CROSS-UK Newsletter 30 (5)
- CROSS-UK Newsletter 31 (3)
- CROSS-UK Newsletter 32 (5)
- CROSS-UK Newsletter 33 (5)
- CROSS-UK Newsletter 34 (1)
- CROSS-UK Newsletter 35 (2)
- CROSS-UK Newsletter 36 (2)
- CROSS-UK Newsletter 37 (4)
- CROSS-UK Newsletter 38 (2)
- CROSS-UK Newsletter 39 (4)
- CROSS-UK Newsletter 40 (2)
- CROSS-UK Newsletter 41 (5)
- CROSS-UK Newsletter 42 (7)
- CROSS-UK Newsletter 43 (2)
- CROSS-UK Newsletter 44 (3)
- CROSS-UK Newsletter 45 (6)
- CROSS-UK Newsletter 46 (3)
- CROSS-UK Newsletter 47 (4)
- CROSS-UK Newsletter 48 (3)
- CROSS-UK Newsletter 49 (6)
- CROSS-UK Newsletter 50 (6)
- CROSS-UK Newsletter 51 (1)
- CROSS-UK Newsletter 52 (3)
- CROSS-UK Newsletter 53 (4)
- CROSS-UK Newsletter 54 (8)
- CROSS-UK Newsletter 55 (4)
- CROSS-UK Newsletter 56 (2)
- CROSS-UK Newsletter 57 (5)
- CROSS-UK Newsletter 58 (3)
- CROSS-UK Newsletter 59 (5)
- CROSS-UK Newsletter 60 (3)
- CROSS-UK Newsletter 67 (1)
- CROSS-UK [sub-heading only] (196)
- CROSS Newsletter (110)
- CROSS Safety Report (252)
- News [sub-heading only] (39)
- Safety information from CROSS [sub-heading only] (1)
CROSS regions
Balustrades in public buildings
A reporter had a concern regarding a timber balustrade in a showroom.
1 February 2007
CROSS Safety Report
Report ID: 61
Region: CROSS-UK
Timber truss
The reporter has been dealing with an application where the engineer involved discovered proprietary timber girder trusses with some glued joints that have come loose.
1 February 2007
CROSS Safety Report
Report ID: 62
Region: CROSS-UK
Effective lengths of load-bearing walls
A reporter raises concerns about masonry walls that they feel do not comply with the limitations on effective length.
1 July 2007
CROSS Safety Report
Report ID: 56
Region: CROSS-UK
Possible galvanising concern
A reporter has a question about using galvanised steel poles for the members of dome structures.
1 November 2006
CROSS Safety Report
Report ID: 48
Region: CROSS-UK
Removal of internal structure
The roof trusses, 6m above the ground floor, had been left supported on props made by nailing floor joists together; one at each party wall position.
1 July 2006
CROSS Safety Report
Report ID: 46
Region: CROSS-UK
Low pitched metal sheet roofs
A reporter is concerned about low pitch metal sheet roofing attached to trussed rafters.
1 April 2007
CROSS Safety Report
Report ID: 66
Region: CROSS-UK
Local authorities and approved inspectors
A reporter is very concerned that the system of building control where there is competition between local authorities and approved inspectors, has produced a situation where the level of independent inspection has fallen dramatically.
1 July 2007
CROSS Safety Report
Report ID: 67
Region: CROSS-UK
Masonry support prop adaptor
A reporter has written to say that when carrying out temporary needling and propping of openings formed in masonry walls one of the most important aspects is to ensure that the props are concentrically loaded and plumb.
1 July 2006
CROSS Safety Report
Report ID: 32
Region: CROSS-UK
Local authority checking
A reporter feels that many small consulting engineering companies rely on local authority building control departments to check their work in lieu of proper in-house quality control.
1 March 2006
CROSS Safety Report
Report ID: 41
Region: CROSS-UK
Wind damage to secondary elements
A period of storm force winds, with wind speeds approaching design levels, resulted in damage to secondary roofing and cladding elements.
1 July 2006
CROSS Safety Report
Report ID: 42
Region: CROSS-UK