Safety information search results
Filter your results
Building or structure type
Materials
Project or lifecycle stage
Design
- BIM (1)
- Computational design (2)
- Design: quality management (7)
- Design calculations (7)
- Design conceptualisation (2)
- Design detailing (10)
- Design drawings (5)
- Design loads (17)
- Design software (3)
- Dynamics (3)
- Fire safety design (5)
- Resilience (1)
- Robustness (3)
- Structural design (21)
- Sustainability (3)
Fire incident response
Method of construction
Structural form
Elements & systems
- Balconies (1)
- Balustrades (2)
- Beams (5)
- Cables (1)
- Canopies (1)
- Ceilings (2)
- Cladding (2)
- Columns (5)
- Fasteners & connections (11)
- Fire protection (2)
- Foundations (2)
- Light gauge steel framing (4)
- Parapets (1)
- PV panels (2)
- Roofs (8)
- Sandwich panels (1)
- Signs (2)
- Slabs (8)
- Trusses (1)
- Walls (9)
- Wall ties (1)
Plant & equipment
Utilities
Safety reporting
Project delivery methods
Business practice
Public incidents
Locations
Content type
- CROSS-AUS Newsletter 2 (6)
- CROSS-AUS Newsletter 3 (6)
- CROSS-AUS Newsletter 4 (6)
- CROSS-AUS Newsletter 5 (4)
- CROSS-AUS Newsletter 8 (2)
- CROSS-AUS [sub-heading only] (17)
- CROSS-UK Newsletter 4 (1)
- CROSS-UK Newsletter 58 (1)
- CROSS-UK [sub-heading only] (1)
- CROSS Safety Alert (22)
- CROSS Safety Report (45)
- CROSS Theme Page (3)
- Safety information from CROSS [sub-heading only] (1)
- Safety information [sub-heading only] (4)
- Third party content (6)
- Third party content (2)
CROSS regions
Structural safety of reinforced autoclaved aerated concrete (RAAC) planks
A Theme Page to raise awareness of and encourage knowledge sharing on the structural safety of RAAC planks.
CROSS Theme Page
Region: CROSS-UK, CROSS-AUS, CROSS-US
Failure of large aluminium composite panel
This report highlights the importance of correctly designed fixings and anchoring systems for cladding panels to buildings to minimize the risk of failure.
30 April 2021
CROSS Safety Report
Report ID: 962
Region: CROSS-AUS
Waterproofing exposed concrete slabs
This report highlights that water ingress into buildings continues to be a problem and discusses the role of the structural engineer when dealing with waterproofing of exposed concrete slabs. It shows how this can be achieved by careful design and detailing of the reinforced concrete structure and by close collaboration of all parties involved.
25 November 2021
CROSS Safety Report
Report ID: 959
Region: CROSS-AUS
Grouting of joints between load-bearing prefabricated concrete members
This report highlights the risk of failure if grouted joints between load-bearing prefabricated concrete members are not designed and installed correctly.
30 April 2021
CROSS Safety Report
Report ID: 961
Region: CROSS-AUS
The myth of quality assurance
This report argues that to achieve the objective of good quality construction that satisfies the design intent there is no substitute for the practice of regular site inspections being conducted by the original design engineer. It questions whether there has been too much reliance on the process of quality assurance systems to the detriment of the quality of the end product.
25 November 2021
CROSS Safety Report
Report ID: 960
Region: CROSS-AUS
Defects found in precast (prefabricated) concrete façades
The reporter found several issues when inspecting or reviewing buildings with precast concrete façades, particularly on older buildings, due to a lack of attention to durability and poor workmanship.
30 March 2023
CROSS Safety Report
Report ID: 995
Region: CROSS-AUS
The use of cast-in ferrules as structural connections
This report highlights several problems that can arise with structural connections between elements when cast-in ferrules (also known as threaded inserts) are used for the anchorage of reinforcing bars.
30 April 2021
CROSS Safety Report
Report ID: 993
Region: CROSS-AUS
Modelling of structures
The reporter is concerned that some structural engineers assume without adequate verification that their computer modelling is correct and accurate; that they do not understand the limitations or basis for their modelling; or that the model chosen may not be appropriate for that structure.
2 August 2022
CROSS Safety Report
Report ID: 994
Region: CROSS-AUS
Use of temporary barriers to control access to hazards
This report highlights the risks associated with the use of temporary barriers to control access to unsafe workplaces. It discusses the issues when scaffolding is used as a barrier, and that this should only be considered for use as a short-term temporary barrier.
25 November 2021
CROSS Safety Report
Report ID: 980
Region: CROSS-AUS
Design of internal partitions for horizontal loads
This report draws attention to the requirement for internal partitions to be designed for horizontal loads from wind and seismic effects in accordance with Section B of the Australian National Construction Code (NCC).
30 April 2021
CROSS Safety Report
Report ID: 1000
Region: CROSS-AUS
Submit a report
Your report will make a difference. It will help to create positive change and improve safety.
Our secure and confidential safety reporting system gives professionals the opportunity to share their experiences to help others.