Safety information search results
Filter your results
Building or structure type
- Bridges (22)
- Buildings
(231)
- Agricultural buildings (8)
- Car parks (7)
- Commercial (19)
- Consequence Class 3 buildings (3)
- Education, science & art buildings (13)
- Higher-risk buildings (3)
- Industrial buildings (9)
- LPS buildings (3)
- Public, religious & civic buildings (6)
- Recreational buildings (3)
- Residential (57)
- Stadiums (1)
- Storage buildings (7)
- Tall buildings (14)
- Theatres & other entertainment buildings (7)
- Transport buildings (1)
- Buried pipes & culverts (3)
- Freestanding walls (2)
- Marine structures (1)
- Masts & towers (9)
- Offshore structures (2)
- Railways (7)
- Reservoirs & dams (1)
- Retaining structures (19)
- Roads (9)
- Sewers (3)
- Temporary structures (24)
- Tunnels (1)
Materials
Project or lifecycle stage
Design
- BIM (2)
- Computational design (2)
- Design: quality management (42)
- Design calculations (45)
- Design conceptualisation (1)
- Design detailing (55)
- Design drawings (14)
- Design loads (67)
- Design software (18)
- Dynamics (6)
- Fire safety design (7)
- Resilience (18)
- Robustness (35)
- Structural design (72)
- Sustainability (4)
Fire incident response
Project type
- Alteration & conversion project (23)
- Assessment project [sub-heading only] (9)
- Conservation & restoration project (1)
- Construction project [sub-heading only] (154)
- Demolition project (11)
- Excavation (12)
- Extension project (11)
- Fire safety assessment (2)
- Groundworks project (1)
- Maintenance project (1)
- New build (70)
- Refurbishment (4)
- Remediation project (11)
- Repair project (5)
- Strengthening project (4)
- Structural assessment (8)
- Underpinning project (3)
Method of construction
Elements & systems
- Arch (5)
- Balconies (9)
- Balustrades (14)
- Basements (7)
- Beams (50)
- Bracing (18)
- Canopies (5)
- Ceilings (19)
- Cladding (17)
- Columns (29)
- Fasteners & connections (96)
- Fire exit doors (1)
- Fire protection (7)
- Foundations (17)
- Insulation (6)
- Light gauge steel framing (2)
- Lintels (3)
- Padstones (3)
- Parapets (7)
- Roofs (37)
- Sandwich panels (1)
- Shear walls (1)
- Signs (3)
- Slabs (28)
- Tendons (1)
- Trusses (4)
- Walls (65)
- Wall ties (7)
- Wind posts (1)
Plant & equipment
Utilities
Safety reporting
Organisations
Project delivery methods
Business practice
Locations
Content type
- CROSS-AUS Newsletter 1 (2)
- CROSS-AUS [sub-heading only] (2)
- CROSS-UK Newsletter 1 (14)
- CROSS-UK Newsletter 2 (10)
- CROSS-UK Newsletter 3 (4)
- CROSS-UK Newsletter 4 (9)
- CROSS-UK Newsletter 5 (7)
- CROSS-UK Newsletter 6 (7)
- CROSS-UK Newsletter 7 (5)
- CROSS-UK Newsletter 8 (6)
- CROSS-UK Newsletter 9 (6)
- CROSS-UK Newsletter 10 (7)
- CROSS-UK Newsletter 11 (5)
- CROSS-UK Newsletter 12 (7)
- CROSS-UK Newsletter 13 (5)
- CROSS-UK Newsletter 14 (5)
- CROSS-UK Newsletter 15 (6)
- CROSS-UK Newsletter 16 (6)
- CROSS-UK Newsletter 17 (6)
- CROSS-UK Newsletter 18 (5)
- CROSS-UK Newsletter 19 (6)
- CROSS-UK Newsletter 20 (6)
- CROSS-UK Newsletter 21 (5)
- CROSS-UK Newsletter 22 (5)
- CROSS-UK Newsletter 23 (8)
- CROSS-UK Newsletter 24 (4)
- CROSS-UK Newsletter 25 (3)
- CROSS-UK Newsletter 26 (5)
- CROSS-UK Newsletter 27 (3)
- CROSS-UK Newsletter 28 (5)
- CROSS-UK Newsletter 29 (6)
- CROSS-UK Newsletter 30 (8)
- CROSS-UK Newsletter 31 (6)
- CROSS-UK Newsletter 32 (8)
- CROSS-UK Newsletter 33 (8)
- CROSS-UK Newsletter 34 (7)
- CROSS-UK Newsletter 35 (6)
- CROSS-UK Newsletter 36 (8)
- CROSS-UK Newsletter 37 (8)
- CROSS-UK Newsletter 38 (7)
- CROSS-UK Newsletter 39 (7)
- CROSS-UK Newsletter 40 (7)
- CROSS-UK Newsletter 41 (7)
- CROSS-UK Newsletter 42 (6)
- CROSS-UK Newsletter 43 (6)
- CROSS-UK Newsletter 44 (7)
- CROSS-UK Newsletter 45 (7)
- CROSS-UK Newsletter 46 (6)
- CROSS-UK Newsletter 47 (8)
- CROSS-UK Newsletter 48 (6)
- CROSS-UK Newsletter 49 (8)
- CROSS-UK Newsletter 50 (7)
- CROSS-UK Newsletter 51 (8)
- CROSS-UK Newsletter 52 (8)
- CROSS-UK Newsletter 53 (6)
- CROSS-UK Newsletter 54 (9)
- CROSS-UK Newsletter 55 (6)
- CROSS-UK Newsletter 56 (7)
- CROSS-UK Newsletter 57 (7)
- CROSS-UK Newsletter 58 (7)
- CROSS-UK Newsletter 59 (6)
- CROSS-UK Newsletter 60 (3)
- (-) CROSS-UK [sub-heading only] (391)
- CROSS Newsletter (198)
- CROSS Safety Report (391)
- News [sub-heading only] (73)
CROSS regions
Deterioration of walkable sandwich panel ceilings
A reporter has raised concern about a complex and potentially far-reaching concern about unseen progressive deterioration in sandwich ceiling panels that have mineral wool lamella cores.
1 October 2007
CROSS Safety Report
Report ID: 54
Region: CROSS-UK
Adapted masonry support props
A reporter has come across adapted masonry support props in use and in their view, they must only be used in the case of limited openings where the masonry can arch over.
1 November 2006
CROSS Safety Report
Report ID: 57
Region: CROSS-UK
Balustrades in public buildings
A reporter had a concern regarding a timber balustrade in a showroom.
1 February 2007
CROSS Safety Report
Report ID: 61
Region: CROSS-UK
Effective lengths of load-bearing walls
A reporter raises concerns about masonry walls that they feel do not comply with the limitations on effective length.
1 July 2007
CROSS Safety Report
Report ID: 56
Region: CROSS-UK
Adapted masonry support props
Another reporter gives their experience on the use of adapted masonry support props.
1 November 2006
CROSS Safety Report
Report ID: 58
Region: CROSS-UK
Fatality from free standing wall collapse
A report was received from a local authority about a boundary wall to the front garden of a domestic property that collapsed suddenly resulting in the death of a child who was passing.
1 January 2008
CROSS Safety Report
Report ID: 59
Region: CROSS-UK
Timber truss
The reporter has been dealing with an application where the engineer involved discovered proprietary timber girder trusses with some glued joints that have come loose.
1 February 2007
CROSS Safety Report
Report ID: 62
Region: CROSS-UK
Facade failure
Large pieces of granite fell without warning from a second floor opening.
1 February 2007
CROSS Safety Report
Report ID: 63
Region: CROSS-UK
Serious injury from free standing wall collapse
A 100mm wide brick masonry wall in a garden collapsed seriously injuring one person.
1 January 2008
CROSS Safety Report
Report ID: 94
Region: CROSS-UK
Site hoardings blow down
Investigations into timber hoarding failures by the reporter’s firm indicated that the majority of site hoardings are erected with no design whatsoever.
1 October 2007
CROSS Safety Report
Report ID: 83
Region: CROSS-UK
Submit a report
Your report will make a difference. It will help to create positive change and improve safety.
Our secure and confidential safety reporting system gives professionals the opportunity to share their experiences to help others.