Safety information search results
Filter your results
Building or structure type
Products
Project or lifecycle stage
Design
Operation or occupation
Codes, standards & regulations
Fire incident response
Construction period
Method of construction
Structural form
Temporary works
Plant & equipment
Utilities
Safety reporting
Project delivery methods
Business practice
Risk management
Theme pages
Content type
- CROSS-UK Newsletter 11 (1)
- CROSS-UK Newsletter 12 (1)
- CROSS-UK Newsletter 20 (1)
- CROSS-UK Newsletter 26 (3)
- CROSS-UK Newsletter 48 (1)
- CROSS-UK Newsletter 56 (1)
- CROSS-UK Newsletter 60 (1)
- CROSS-UK [sub-heading only] (7)
- CROSS Newsletter (2)
- CROSS Safety Alert (1)
- CROSS Safety Report (16)
- CROSS Topic Paper (1)
- News [sub-heading only] (1)
CROSS regions
Fire in multi-storey car parks
The severe fire at the Liverpool Echo Arena MSCP on 31st December 2017 gutted the seven-storey building and up to 1,400 cars were destroyed.
1 February 2018
CROSS Safety Alert
Region: CROSS-UK, CROSS-AUS, CROSS-US
Elliot Lake mall collapse
In June 2012 part of the roof of a thirty two year old Mall in Ontario, Canada collapsed killing two people and injuring nineteen.
1 December 2014
CROSS Topic Paper
Region: CROSS-UK
Multi storey car park defects
A reporter has been concerned for some time that there potentially could be another failure similar to Pipers Row in Wolverhampton and raises their concerns.
1 October 2008
CROSS Safety Report
Report ID: 119
Region: CROSS-UK
Car park mesh barriers
A reporter is concerned that barrier systems that do not comply with the current standards may be used in car parks throughout Britain.
1 October 2008
CROSS Safety Report
Report ID: 120
Region: CROSS-UK
Car park staircase collapse at construction joint
The top flight of a staircase to a multi-storey concrete car park collapsed approximately 10 years after construction.
1 July 2008
CROSS Safety Report
Report ID: 106
Region: CROSS-UK
Thermal effects on long span concrete car park beams
A reporter describes how long span precast hollow core units in a car park started to bow upwards due to thermal effects.
1 October 2010
CROSS Safety Report
Report ID: 173
Region: CROSS-UK
Car park barrier failure
A reporter discusses the load capacity of barriers in car parks following the failure of a barrier which caused a fatality.
1 July 2013
CROSS Safety Report
Report ID: 352
Region: CROSS-UK
Further Multi-Storey Car Park (MSCP) concerns
A reporter raises their concerns over the potential safety issue of older car parks that are suffering neglect through lack of inspection and routine maintenance.
1 January 2009
CROSS Safety Report
Report ID: 127
Region: CROSS-UK
Structural assessments of multi-storey car parks
The parking industry has in recent years (2012) seen several MSCPs closed due to structural fears, says a reporter, which begs the question how close were they to structural failure before they were taken out of service?
1 April 2012
CROSS Safety Report
Report ID: 224
Region: CROSS-UK
Demolition of Multi-Storey Car Park (MSCP) reveals poor concrete
During the demolition of a MSCP, the quality of the concrete in critical load bearing members was found to be extremely poor.
1 January 2014
CROSS Safety Report
Report ID: 313
Region: CROSS-UK
Submit a report