Safety information search results
Filter your results
Building or structure type
- Bridges (12)
- (-)
Buildings
(199)
- Agricultural buildings (8)
- Car parks (7)
- Commercial (19)
- Consequence Class 3 buildings (3)
- Education, science & art buildings (11)
- Health care (2)
- Higher-risk buildings (4)
- Industrial buildings (5)
- Laboratory buildings (1)
- Nuclear & energy buildings (1)
- Public, religious & civic buildings (7)
- Recreational buildings (6)
- Residential (48)
- Stadiums (2)
- Storage buildings (6)
- Tall buildings (12)
- Theatres & other entertainment buildings (5)
- Transport buildings (2)
- Buried pipes & culverts (1)
- Floating structures (1)
- Freestanding walls (2)
- Marine structures (1)
- Masts & towers (3)
- Railways (3)
- Reservoirs & dams (1)
- Retaining structures (5)
- Roads (2)
- Sewers (1)
- Temporary structures (2)
Materials
Project or lifecycle stage
Design
- BIM (2)
- Computational design (9)
- Design: quality management (37)
- Design calculations (50)
- Design conceptualisation (26)
- Design detailing (70)
- Design drawings (21)
- Design loads (55)
- Design software (21)
- Dynamics (5)
- Fire safety design (6)
- Resilience (12)
- Robustness (30)
- Structural design (69)
- Sustainability (5)
Fire incident response
Project type
- Alteration & conversion project (21)
- Assessment project [sub-heading only] (6)
- Conservation & restoration project (2)
- Construction project [sub-heading only] (76)
- Excavation (2)
- Extension project (13)
- Groundworks project (1)
- Maintenance project (2)
- New build (30)
- Refurbishment (13)
- Remediation project (9)
- Repair project (5)
- Strengthening project (3)
- Structural assessment (14)
- Underpinning project (2)
Construction period
Method of construction
Elements & systems
- Arch (1)
- Balconies (4)
- Balustrades (8)
- Basements (7)
- Beams (31)
- Bracing (10)
- Canopies (1)
- Ceilings (7)
- Cladding (18)
- Columns (21)
- Fasteners & connections (50)
- Fences (1)
- Fire protection (5)
- Foundations (5)
- Insulation (7)
- Light gauge steel framing (3)
- Padstones (2)
- Parapets (4)
- PV panels (3)
- Roofs (43)
- Sandwich panels (2)
- Shear walls (1)
- Signs (1)
- Slabs (19)
- Trusses (8)
- Walls (28)
- Wall ties (4)
Plant & equipment
Utilities
Safety reporting
Organisations
Business practice
Content type
- CROSS-AUS Newsletter 1 (1)
- CROSS-AUS Newsletter 2 (1)
- CROSS-AUS Newsletter 3 (1)
- CROSS-AUS [sub-heading only] (3)
- CROSS-UK Newsletter 1 (1)
- CROSS-UK Newsletter 2 (3)
- CROSS-UK Newsletter 3 (1)
- CROSS-UK Newsletter 4 (2)
- CROSS-UK Newsletter 5 (2)
- CROSS-UK Newsletter 6 (1)
- CROSS-UK Newsletter 7 (3)
- CROSS-UK Newsletter 8 (2)
- CROSS-UK Newsletter 9 (2)
- CROSS-UK Newsletter 11 (2)
- CROSS-UK Newsletter 12 (1)
- CROSS-UK Newsletter 13 (1)
- CROSS-UK Newsletter 19 (1)
- CROSS-UK Newsletter 20 (3)
- CROSS-UK Newsletter 22 (1)
- CROSS-UK Newsletter 23 (7)
- CROSS-UK Newsletter 24 (2)
- CROSS-UK Newsletter 25 (2)
- CROSS-UK Newsletter 26 (2)
- CROSS-UK Newsletter 28 (1)
- CROSS-UK Newsletter 29 (1)
- CROSS-UK Newsletter 31 (3)
- CROSS-UK Newsletter 32 (4)
- CROSS-UK Newsletter 33 (4)
- CROSS-UK Newsletter 34 (1)
- CROSS-UK Newsletter 35 (1)
- CROSS-UK Newsletter 36 (1)
- CROSS-UK Newsletter 37 (2)
- CROSS-UK Newsletter 39 (1)
- CROSS-UK Newsletter 41 (5)
- CROSS-UK Newsletter 42 (3)
- CROSS-UK Newsletter 43 (3)
- CROSS-UK Newsletter 44 (2)
- CROSS-UK Newsletter 45 (2)
- CROSS-UK Newsletter 46 (1)
- CROSS-UK Newsletter 48 (2)
- CROSS-UK Newsletter 49 (1)
- CROSS-UK Newsletter 50 (3)
- CROSS-UK Newsletter 51 (2)
- CROSS-UK Newsletter 52 (1)
- CROSS-UK Newsletter 54 (5)
- CROSS-UK Newsletter 55 (3)
- CROSS-UK Newsletter 56 (3)
- CROSS-UK Newsletter 57 (2)
- CROSS-UK Newsletter 58 (3)
- CROSS-UK Newsletter 59 (3)
- CROSS-UK Newsletter 60 (5)
- CROSS-UK Newsletter 61 (2)
- CROSS-UK Newsletter 62 (2)
- CROSS-UK Newsletter 64 (4)
- CROSS-UK Newsletter 65 (4)
- CROSS-UK Newsletter 67 (5)
- CROSS-UK Newsletter 68 (4)
- CROSS-UK [sub-heading only] (102)
- CROSS-US Newsletter 1 (2)
- CROSS-US Newsletter 2 (3)
- CROSS-US [sub-heading only] (5)
- CROSS Newsletter (64)
- CROSS Safety Alert (2)
- CROSS Safety Report (190)
- CROSS Topic Paper (3)
- News [sub-heading only] (24)
- Safety information from CROSS [sub-heading only] (1)
- Safety information [sub-heading only] (1)
- Third party content (4)
- Third party content (2)
CROSS regions
Building regulations checking
A reporter’s firm has been carrying out building regulations checks for 25 years, but it is only in the last six or seven years (say 2000-2006) that concerns have arisen, some of which are described below.
1 July 2007
CROSS Safety Report
Report ID: 33
Region: CROSS-UK
Stability of timber frame construction
A reporter who has many years design experience in timber frame construction raises concerns about a common defect they have experienced when checking calculations.
1 February 2007
CROSS Safety Report
Report ID: 51
Region: CROSS-UK
Design of head track in cold formed steel framing
The reporter noticed that the in-house structural engineer for the steel frame company had not taken account of all the loads in the design of the head track.
1 November 2006
CROSS Safety Report
Report ID: 39
Region: CROSS-UK
Structural failure of older timber connections
A reporter shares three examples of the structural failure or inadequacies of connections in existing timber structures that they have encountered.
13 December 2021
CROSS Safety Report
Report ID: 1040
Region: CROSS-UK
Structural safety when designing lean in the climate emergency
The IStructE Safety, Health and Wellbeing Panel considers the safety implications when aspiring to a lean design.
4 January 2021
Third party content
Publisher: The Institution of Structural Engineers
Structural fire safety when responding to the climate emergency
Luke Bisby urges structural engineers to improve their understanding of ‘fire resistance’ as the profession looks to innovate rapidly in response to climate change.
1 February 2021
Third party content
Publisher: The Institution of Structural Engineers
The risk of collapse of multi-storey CLT buildings during a fire
A reporter presents concerns about the fire safety of multi-storey buildings comprised of cross-laminated timber (CLT) structures.
29 March 2021
CROSS Safety Report
Report ID: 966
Region: CROSS-UK
Risks associated with steel gates
A reporter has noticed recurring defects with large gates in residential apartment complexes, including at least three where there were serious incidents, one involving a fatality.
30 July 2021
CROSS Safety Report
Report ID: 1021
Region: CROSS-UK
Brick slips falling from height
A reporter describes cases of brick slips falling from height due to adhesive failures and considers that there is a danger to the public.
13 August 2021
CROSS Safety Report
Report ID: 1017
Region: CROSS-UK
Concerns about punching shear in a flat slab
This report concerns potential shear failures in flat slabs. This originates from inconsistent design and detailing of the shear reinforcement where a proprietary shear link system is assumed in the design but not followed in detailing.
13 December 2021
CROSS Safety Report
Report ID: 1050
Region: CROSS-UK