Unsafe design of retrofit cantilever balconies
A structural assessment of a number of new balconies being added to an existing building revealed critical concerns in respect of fixings back into the existing brickwork.
26 August 2022
CROSS Safety Report
Report ID: 1128
Region: CROSS-UK
Misleading instructions for a structural component
A reporter confirms the difficulty encountered whilst endeavouring to ensure cast-in insulated connectors supporting a parapet wall and balustrade were properly fixed.
26 August 2022
CROSS Safety Report
Report ID: 1127
Region: CROSS-UK
Risks associated with historic stone balconies
A reporter highlights the structural issues of a stone balcony they encountered when working on a Grade II listed terrace house.
13 December 2021
CROSS Safety Report
Report ID: 1001
Region: CROSS-UK
Glass panel fixings failure
A local authority reports how a double-laminated glass panel measuring approximately 1mx1.5m fell from a first floor balcony, striking four people who were standing on the ground floor.
1 October 2010
CROSS Safety Report
Report ID: 182
Region: CROSS-UK
Open balustrade balconies over a public highway
A reporter raises concerns about the construction of a large residential development adjacent to a public highway where the balconies over sail the footpath.
1 October 2015
CROSS Safety Report
Report ID: 495
Region: CROSS-UK
Dangerous glass infill panels on balustrade
A reporter has expressed their concern about the structural stability of cantilever glass infill panels between a steel post and handrail balustrade system at a high-level apartment block.
1 January 2019
CROSS Safety Report
Report ID: 741
Region: CROSS-UK
Non compliant guard rails on high rise apartment buildings after modification
A reporter is seeing many high rise apartment buildings having balcony and walkway decks replaced and, in some instances, the increased height of the decks has resulted in the guard rails being less than 1100mm high meaning they are no longer compliant.
20 February 2024
CROSS Safety Report
Report ID: 1221
Region: CROSS-UK