Safety information search results
Filter your results
Building or structure type
- Bridges (2)
- Buildings
(83)
- Car parks (3)
- Commercial (16)
- Education, science & art buildings (12)
- Health care (11)
- Higher-risk buildings (5)
- Industrial buildings (9)
- LPS buildings (2)
- Public, religious & civic buildings (1)
- Recreational buildings (2)
- Residential (49)
- Tall buildings (9)
- Theatres & other entertainment buildings (2)
Project or lifecycle stage
Design
Operation or occupation
Fire incident response
Project type
Method of construction
Structural form
Elements & systems
Temporary works
Plant & equipment
Utilities
Safety reporting
Project delivery methods
Business practice
Risk management
Content type
- CROSS-AUS Newsletter 4 (2)
- CROSS-AUS [sub-heading only] (2)
- CROSS-UK Newsletter 8 (1)
- CROSS-UK Newsletter 12 (1)
- CROSS-UK Newsletter 16 (1)
- CROSS-UK Newsletter 18 (1)
- CROSS-UK Newsletter 20 (1)
- CROSS-UK Newsletter 35 (1)
- CROSS-UK Newsletter 47 (1)
- CROSS-UK Newsletter 48 (1)
- CROSS-UK Newsletter 49 (2)
- CROSS-UK Newsletter 50 (1)
- CROSS-UK Newsletter 51 (1)
- CROSS-UK Newsletter 55 (2)
- CROSS-UK Newsletter 56 (1)
- CROSS-UK Newsletter 57 (1)
- CROSS-UK Newsletter 59 (2)
- CROSS-UK Newsletter 61 (2)
- CROSS-UK Newsletter 62 (6)
- CROSS-UK Newsletter 64 (5)
- CROSS-UK Newsletter 65 (5)
- CROSS-UK Newsletter 67 (5)
- CROSS-UK Newsletter 68 (6)
- CROSS-UK [sub-heading only] (16)
- CROSS Feature Article (1)
- CROSS Newsletter (18)
- CROSS Safety Alert (5)
- CROSS Safety Report (86)
- CROSS Theme Page (2)
- CROSS Topic Paper (3)
- News [sub-heading only] (2)
- Third party content (3)
- Third party content (1)
CROSS regions
Corrosion of fixings securing fire resisting plasterboard
A reporter sent pictures from a site where metal plasterboard fixings had deteriorated not long after installation.
1 July 2014
CROSS Safety Report
Report ID: 375
Region: CROSS-UK
Front doors in blocks of flats - security versus safety?
Fire doors in blocks of flats changed for security doors not meeting fire safety requirements.
13 December 2021
CROSS Safety Report
Report ID: 893
Region: CROSS-UK
The risk of collapse of multi-storey CLT buildings during a fire
A reporter presents concerns about the fire safety of multi-storey buildings comprised of cross-laminated timber (CLT) structures.
29 March 2021
CROSS Safety Report
Report ID: 966
Region: CROSS-UK
Major safety defects in hospital
A number of construction defects were found in a hospital following the inspection of the external wall system.
29 March 2021
CROSS Safety Report
Report ID: 826
Region: CROSS-UK
Fire exit chained closed due to COVID-19 concerns
A key pad operated fire exit was chained closed to prevent the spread of COVID-19.
13 August 2021
CROSS Safety Report
Report ID: 975
Region: CROSS-UK
Fire safety concern over green walls
This report discusses how building close down procedures that include isolating automated water systems might result in the drying out of green walls, thus presenting a significant fire hazard in external walls.
13 August 2021
CROSS Safety Report
Report ID: 976
Region: CROSS-UK
COVID-19 and the impact on construction quality
A reporter is concerned that during the Covid lockdowns, there may have been work done without adequate independent supervision.
17 November 2022
CROSS Safety Report
Report ID: 967
Region: CROSS-UK
Fire protection to car park steel frame
A reporter is concerned about the fire protection of a steel framed car park above a retail unit.
26 August 2022
CROSS Safety Report
Report ID: 1007
Region: CROSS-UK
Combustible cladding material ignited during remediation work
Damage to combustible insulation on the external walls of a high rise residential premises was noticed from apparent combustion within the EPS element.
21 August 2023
CROSS Safety Report
Report ID: 1222
Region: CROSS-UK
Non approved sealants are used with CPVC pipes and fittings
A reporter highlights a concern when non approved sealants are used with chlorinated polyvinyl chloride (CPVC) sprinkler system pipework and fittings. This can cause failures and/or leaks.
20 February 2024
CROSS Safety Report
Report ID: 1228
Region: CROSS-UK
Submit a report
Your report will make a difference. It will help to create positive change and improve safety.
Our secure and confidential safety reporting system gives professionals the opportunity to share their experiences to help others.