Safety information search results
Filter your results
Building or structure type
- Bridges (2)
- Buildings
(83)
- Car parks (3)
- Commercial (16)
- Education, science & art buildings (12)
- Health care (11)
- Higher-risk buildings (5)
- Industrial buildings (9)
- LPS buildings (2)
- Public, religious & civic buildings (1)
- Recreational buildings (2)
- Residential (49)
- Tall buildings (9)
- Theatres & other entertainment buildings (2)
Project or lifecycle stage
Design
Operation or occupation
Fire incident response
Project type
Method of construction
Structural form
Elements & systems
Temporary works
Plant & equipment
Utilities
Safety reporting
Project delivery methods
Business practice
Risk management
Content type
- CROSS-AUS Newsletter 4 (2)
- CROSS-AUS [sub-heading only] (2)
- CROSS-UK Newsletter 8 (1)
- CROSS-UK Newsletter 12 (1)
- CROSS-UK Newsletter 16 (1)
- CROSS-UK Newsletter 18 (1)
- CROSS-UK Newsletter 20 (1)
- CROSS-UK Newsletter 35 (1)
- CROSS-UK Newsletter 47 (1)
- CROSS-UK Newsletter 48 (1)
- CROSS-UK Newsletter 49 (2)
- CROSS-UK Newsletter 50 (1)
- CROSS-UK Newsletter 51 (1)
- CROSS-UK Newsletter 55 (2)
- CROSS-UK Newsletter 56 (1)
- CROSS-UK Newsletter 57 (1)
- CROSS-UK Newsletter 59 (2)
- CROSS-UK Newsletter 61 (2)
- CROSS-UK Newsletter 62 (6)
- CROSS-UK Newsletter 64 (5)
- CROSS-UK Newsletter 65 (5)
- CROSS-UK Newsletter 67 (5)
- CROSS-UK Newsletter 68 (6)
- CROSS-UK [sub-heading only] (16)
- CROSS Feature Article (1)
- CROSS Newsletter (18)
- CROSS Safety Alert (5)
- CROSS Safety Report (86)
- CROSS Theme Page (2)
- CROSS Topic Paper (3)
- News [sub-heading only] (2)
- Third party content (3)
- Third party content (1)
CROSS regions
Corrosion of fixings securing fire resisting plasterboard
A reporter sent pictures from a site where metal plasterboard fixings had deteriorated not long after installation.
1 July 2014
CROSS Safety Report
Report ID: 375
Region: CROSS-UK
Fire evacuation concerns from large panel system tower blocks
A reporter highlights concerns about how alterations to a large panel system (LPS) roof may affect any evacuations from the rooftop by helicopter rescues.
1 April 2010
CROSS Safety Report
Report ID: 160
Region: CROSS-UK
Resources in a recession
A reporter raises concerns with a company’s decision to transfer an incomplete design of a large complicated project from one department to another due to budget overspend and lack of work to latter department.
1 October 2009
CROSS Safety Report
Report ID: 161
Region: CROSS-UK
Do current regulations apply when repairing older buildings?
A 19th century three story mill was subject to a fire which resulted in the sudden collapse of part of the interior structure.
1 October 2010
CROSS Safety Report
Report ID: 212
Region: CROSS-UK
Behaviour of Phase Change Materials in fire when incorporated in linings in buildings
A reporter raised a concern regarding the perception and use of products that incorporate Phase Change Materials (PCMs).
24 May 2023
CROSS Safety Report
Report ID: 698
Region: CROSS-UK
Fire exit chained closed due to COVID-19 concerns
A key pad operated fire exit was chained closed to prevent the spread of COVID-19.
13 August 2021
CROSS Safety Report
Report ID: 975
Region: CROSS-UK
Fire safety concern over green walls
This report discusses how building close down procedures that include isolating automated water systems might result in the drying out of green walls, thus presenting a significant fire hazard in external walls.
13 August 2021
CROSS Safety Report
Report ID: 976
Region: CROSS-UK
Front doors in blocks of flats - security versus safety?
Fire doors in blocks of flats changed for security doors not meeting fire safety requirements.
13 December 2021
CROSS Safety Report
Report ID: 893
Region: CROSS-UK
Brick slips falling from height
A reporter describes cases of brick slips falling from height due to adhesive failures and considers that there is a danger to the public.
13 August 2021
CROSS Safety Report
Report ID: 1017
Region: CROSS-UK
Fire protection of stair structure
A reporter is concerned about the lack of structural fire protection in a fire escape stair.
10 March 2022
CROSS Safety Report
Report ID: 1028
Region: CROSS-UK
Submit a report
Your report will make a difference. It will help to create positive change and improve safety.
Our secure and confidential safety reporting system gives professionals the opportunity to share their experiences to help others.