Safety information search results
Filter your results
Building or structure type
Materials
Project or lifecycle stage
Design
- BIM (1)
- Computational design (2)
- Design: quality management (7)
- Design calculations (7)
- Design conceptualisation (2)
- Design detailing (10)
- Design drawings (5)
- Design loads (17)
- Design software (3)
- Dynamics (3)
- Fire safety design (5)
- Resilience (1)
- Robustness (3)
- Structural design (21)
- Sustainability (3)
Fire incident response
Method of construction
Structural form
Elements & systems
- Balconies (1)
- Balustrades (2)
- Beams (5)
- Cables (1)
- Canopies (1)
- Ceilings (2)
- Cladding (2)
- Columns (5)
- Fasteners & connections (11)
- Fire protection (2)
- Foundations (2)
- Light gauge steel framing (4)
- Parapets (1)
- PV panels (2)
- Roofs (8)
- Sandwich panels (1)
- Signs (2)
- Slabs (8)
- Trusses (1)
- Walls (9)
- Wall ties (1)
Plant & equipment
Utilities
Safety reporting
Project delivery methods
Business practice
Public incidents
Locations
Content type
- CROSS-AUS Newsletter 2 (6)
- CROSS-AUS Newsletter 3 (6)
- CROSS-AUS Newsletter 4 (6)
- CROSS-AUS Newsletter 5 (4)
- CROSS-AUS Newsletter 8 (2)
- CROSS-AUS [sub-heading only] (17)
- CROSS-UK Newsletter 4 (1)
- CROSS-UK Newsletter 58 (1)
- CROSS-UK [sub-heading only] (1)
- CROSS Safety Alert (22)
- CROSS Safety Report (45)
- CROSS Theme Page (2)
- Safety information from CROSS [sub-heading only] (1)
- Safety information [sub-heading only] (4)
- Third party content (6)
- Third party content (2)
CROSS regions
Site testing of post-installed fasteners in concrete
This report describes a situation where site testing of post-installed fasteners in concrete was undertaken by a contractor as an alternative to adopting the design data from the manufacturer in an attempt to justify an increased design capacity for the fasteners.
2 August 2022
CROSS Safety Report
Report ID: 1091
Region: CROSS-AUS
Snow loading on buildings
In 2010 there was heavy snow in many parts of the UK, but particularly in Scotland, where a number of buildings, mainly agricultural, collapsed under the weight of snow (up to 1.2m in some cases).
1 February 2010
CROSS Safety Alert
Region: CROSS-UK, CROSS-AUS, CROSS-US
Punching shear in concrete slabs at perimeter columns
A reporter raises concerns about the underestimation of bending moments in perimeter columns when assessing punching shear in adjacent concrete slabs. Punching shear failures can be brittle and catastrophic. Designers need to include the appropriate ultimate moment in the design actions.
14 October 2022
CROSS Safety Report
Report ID: 1122
Region: CROSS-AUS
Continuously threaded reinforcing bar
This report highlights the difficulty of inspecting continuously threaded reinforcing bars to ensure that they have been adequately inserted into the cast-in ferrules.
2 August 2022
CROSS Safety Report
Report ID: 1074
Region: CROSS-AUS
Construction products- fire test certificates
A reporter has notified CROSS-AUS regarding the potentially inappropriate use of regulatory/compliance fire test methods on certain products. This has led, they say, to the circulation of inaccurate test certificates in the market and possibly the use of these products on buildings where they may not be suitable.
2 August 2022
CROSS Safety Report
Report ID: 1060
Region: CROSS-AUS
The management of design related risks: structural, civil and fire engineers
Significant, and tragic, failures involving structures continue to occur: fires in apartment blocks in Milan, London and Taiwan, and structural collapses in Florida and Nigeria being recent examples. This paper gives emphasis to the need for engineers to consider risk management at a fundamental level.
15 December 2021
CROSS Safety Alert
Region: CROSS-UK, CROSS-AUS, CROSS-US
Safety issues associated with balconies
This Alert draws attention to the safety risks associated with balconies, both new and existing. It draws on confidential reporting experience from the UK, from Australia, New Zealand and from the USA.
17 February 2022
CROSS Safety Alert
Region: CROSS-UK, CROSS-AUS, CROSS-US
The reliability of technical data for proprietary products
This report highlights the importance of verifying technical data provided by the manufacturer or supplier of proprietary products.
25 November 2021
CROSS Safety Report
Report ID: 1080
Region: CROSS-AUS
Inadequate modelling of existing building
An existing building suffered damage while being upgraded, which led to a more detailed inspection of the existing building’s condition. The report highlights the importance of conducting a thorough investigation and assessment of an existing building structure to ensure an understanding of how it will perform under the applied design loads, rather than relying on assumptions that may be unre...
30 March 2023
CROSS Safety Report
Report ID: 1082
Region: CROSS-AUS
Condition assessments of exposed lightweight canopy roofs
Defects in lightweight canopy roofs, using underslung roofing sheets in many cases.
14 October 2022
CROSS Safety Report
Report ID: 1084
Region: CROSS-AUS
Submit a report
Your report will make a difference. It will help to create positive change and improve safety.
Our secure and confidential safety reporting system gives professionals the opportunity to share their experiences to help others.