CROSS regions
Stadia crash barriers
Some hollow steel posts forming part of a crash barrier, which were only 4-5 years old, had filled with water that had caused the damage on freezing in winter.
1 February 2001
CROSS Safety Alert
Region: CROSS-UK
Cladding - the case for improving inspection
A review of SCOSS reports from 1977 - 2000 pointed up the problems relating to design and inspection of cladding, and the difficulties of changing bad and sometimes unsafe practice.
1 May 2000
CROSS Safety Alert
Region: CROSS-UK
Concrete system buildings - need for period inspection
Evidence of corrosion of tendons in post-tensioned components came to light which was associated with exposure of tendons to moisture in voids in ducts and sometimes also the presence of chlorides.
1 December 2001
CROSS Safety Alert
Region: CROSS-UK
Snow loading on buildings
In 2010 there was heavy snow in many parts of the UK, but particularly in Scotland, where a number of buildings, mainly agricultural, collapsed under the weight of snow (up to 1.2m in some cases).
1 February 2010
CROSS Safety Alert
Region: CROSS-UK, CROSS-AUS, CROSS-US
Gross errors fear in structural timber design
SCOSS received a report in 2002 expressing concern that standards of structural timber design achieved by many designers fall far short of those needed to give assurance of safety.
1 January 2002
CROSS Safety Alert
Region: CROSS-UK
Failure of cast iron beams
In 1988 there was a collapse of a cast iron roof beam within a jack arch construction, in a house within a London terrace.
1 January 2003
CROSS Safety Alert
Region: CROSS-UK
Installation of timber joist hangers
Joist hanger failures have been found to occur as a result of several types of building defects as listed in the Alert.
1 July 2006
CROSS Safety Alert
Region: CROSS-UK
The selection and installation of construction fixings
SCOSS has been concerned for some time at the use of structural fixings where these so called minor items have not received the attention they deserve given their safety critical nature.
1 September 2010
CROSS Safety Alert
Region: CROSS-UK, CROSS-AUS, CROSS-US
Temporary event structures - saddle span type tents
Saddle span type tented structures appear to provide effective solutions to the needs of event organisers. However, they require careful design, erection and management and a list of precautions is given in the Alert.
1 October 2010
CROSS Safety Alert
Region: CROSS-UK, CROSS-AUS, CROSS-US
The management of design related risks: structural, civil and fire engineers
Significant, and tragic, failures involving structures continue to occur: fires in apartment blocks in Milan, London and Taiwan, and structural collapses in Florida and Nigeria being recent examples. This paper gives emphasis to the need for engineers to consider risk management at a fundamental level.