Safety information search results
Filter your results
Building or structure type
- Bridges (34)
- Buildings
(295)
- Agricultural buildings (6)
- Car parks (11)
- Commercial (30)
- Consequence Class 3 buildings (1)
- Education, science & art buildings (30)
- Health care (14)
- Higher-risk buildings (4)
- Industrial buildings (18)
- Laboratory buildings (1)
- LPS buildings (3)
- Nuclear & energy buildings (1)
- Public, religious & civic buildings (10)
- Recreational buildings (6)
- Residential (98)
- Stadiums (2)
- Storage buildings (9)
- Tall buildings (9)
- Theatres & other entertainment buildings (8)
- Transport buildings (2)
- Buried pipes & culverts (2)
- Floating structures (1)
- Freestanding walls (3)
- Marine structures (2)
- Masts & towers (9)
- Offshore structures (1)
- Railways (6)
- Reservoirs & dams (1)
- Retaining structures (24)
- Roads (6)
- Sewers (3)
- Temporary structures (18)
- Tunnels (2)
Building height
Materials
Project or lifecycle stage
Design
- BIM (3)
- Computational design (11)
- Design: quality management (36)
- Design calculations (44)
- Design conceptualisation (24)
- Design detailing (56)
- Design drawings (22)
- Design loads (58)
- Design software (16)
- Dynamics (7)
- Fire safety design (8)
- Resilience (19)
- Robustness (44)
- Structural design (68)
- Sustainability (2)
Codes, standards & regulations
Fire incident response
Project type
- Alteration & conversion project (29)
- Assessment project [sub-heading only] (8)
- Conservation & restoration project (2)
- Construction project [sub-heading only] (118)
- Demolition project (5)
- Excavation (4)
- Extension project (13)
- Groundworks project (1)
- Maintenance project (1)
- New build (44)
- Refurbishment (19)
- Remediation project (7)
- Repair project (6)
- Strengthening project (2)
- Structural assessment (16)
- Underpinning project (4)
Construction period
Method of construction
Elements & systems
- Arch (5)
- Balconies (7)
- Balustrades (11)
- Basements (7)
- Beams (32)
- Bracing (10)
- Cables (1)
- Canopies (5)
- Ceilings (15)
- Cladding (26)
- Columns (20)
- Fasteners & connections (96)
- Fences (1)
- Fire exit doors (1)
- Fire protection (5)
- Foundations (22)
- Insulation (6)
- Light gauge steel framing (6)
- Lintels (3)
- Padstones (3)
- Parapets (5)
- PV panels (3)
- Roofs (48)
- Sandwich panels (3)
- Shear walls (2)
- Signs (2)
- Slabs (32)
- Tendons (1)
- Trusses (6)
- Wall head restraints (1)
- Walls (69)
- Wall ties (8)
Plant & equipment
Weather & natural hazards
Utilities
Safety reporting
Organisations
Project delivery methods
Business practice
Content type
- CROSS-AUS Newsletter 5 (4)
- CROSS-AUS Newsletter 8 (2)
- CROSS-UK Newsletter 1 (16)
- CROSS-UK Newsletter 2 (10)
- CROSS-UK Newsletter 3 (4)
- CROSS-UK Newsletter 4 (8)
- CROSS-UK Newsletter 5 (7)
- CROSS-UK Newsletter 6 (7)
- CROSS-UK Newsletter 7 (5)
- CROSS-UK Newsletter 8 (6)
- CROSS-UK Newsletter 9 (6)
- CROSS-UK Newsletter 10 (7)
- CROSS-UK Newsletter 11 (5)
- CROSS-UK Newsletter 12 (8)
- CROSS-UK Newsletter 13 (6)
- CROSS-UK Newsletter 14 (5)
- CROSS-UK Newsletter 15 (6)
- CROSS-UK Newsletter 16 (6)
- CROSS-UK Newsletter 17 (6)
- CROSS-UK Newsletter 18 (5)
- CROSS-UK Newsletter 19 (6)
- CROSS-UK Newsletter 20 (6)
- CROSS-UK Newsletter 21 (5)
- CROSS-UK Newsletter 22 (5)
- CROSS-UK Newsletter 23 (8)
- CROSS-UK Newsletter 24 (4)
- CROSS-UK Newsletter 25 (3)
- CROSS-UK Newsletter 26 (4)
- CROSS-UK Newsletter 27 (3)
- CROSS-UK Newsletter 28 (2)
- CROSS-UK Newsletter 29 (3)
- CROSS-UK Newsletter 31 (1)
- CROSS-UK Newsletter 42 (1)
- CROSS-UK Newsletter 61 (4)
- CROSS-UK Newsletter 62 (9)
- CROSS-UK Newsletter 64 (9)
- CROSS-UK Newsletter 65 (10)
- CROSS-UK Newsletter 67 (10)
- CROSS-UK Newsletter 68 (10)
- CROSS-UK [sub-heading only] (169)
- CROSS-US Newsletter 3 (5)
- CROSS Newsletter (29)
- (-) CROSS Safety Report (439)
- News [sub-heading only] (36)
- Safety information from CROSS [sub-heading only] (1)
- Safety information [sub-heading only] (4)
CROSS regions
Collapse of brick arch overbridge during demolition
A reporter describes a project where a flanking brick arch collapsed during the demolition of two multi-span bridges over rail lines.
30 June 2022
CROSS Safety Report
Report ID: 573
Region: CROSS-UK
Failure of cast-in wire lifting loops on manhole cover slabs
A cast-in wire lifting loop failed when lifting a 4m diameter precast manhole cover slab into place.
23 May 2022
CROSS Safety Report
Report ID: 629
Region: CROSS-UK
Behaviour of Phase Change Materials in fire when incorporated in linings in buildings
A reporter raised a concern regarding the perception and use of products that incorporate Phase Change Materials (PCMs).
24 May 2023
CROSS Safety Report
Report ID: 698
Region: CROSS-UK
Fatigue failure of bridge cross-girder
During a planned examination of a bridge, a cross-girder was found to have failed via fatigue.
23 May 2022
CROSS Safety Report
Report ID: 743
Region: CROSS-UK
Overall stability of building proposed to be provided by metal framing and plasterboard
Metal framing and plasterboard was used to provide lateral stability to a building. The form of construction was later deemed to be unsuitable and extensive remedial works had to be carried out.
24 May 2023
CROSS Safety Report
Report ID: 468
Region: CROSS-UK
Failure of vertical bracing system in coffee shop
A reporter noticed that a bolt at a low level connecting node of the vertical bracing system in a public building had failed.
30 June 2022
CROSS Safety Report
Report ID: 759
Region: CROSS-UK
Dangerous defects in curtain wall glazing
This report concerns a 5m high vertical glazing system in which the fixings for a panel failed after only four years because of a lack of co-ordination between designers and contractors.
6 April 2023
CROSS Safety Report
Report ID: 762
Region: CROSS-UK
Corrosion of bridge girder beams
Severe corrosion of bridge girder beams was found during intrusive inspections.
23 May 2022
CROSS Safety Report
Report ID: 772
Region: CROSS-UK
Accelerated corrosion of telecoms mast holding down bolts
During an examination of a 20m high telecoms mast, a reporter found that there had been accelerated corrosion of the galvanised holding down bolts.
1 June 2022
CROSS Safety Report
Report ID: 773
Region: CROSS-UK
Failure of prestressed hollowcore units during storage and transport
A reporter shares their experience of the failure of prestressed hollowcore units during storage and transport.
1 June 2022
CROSS Safety Report
Report ID: 748
Region: CROSS-UK
Submit a report
Your report will make a difference. It will help to create positive change and improve safety.
Our secure and confidential safety reporting system gives professionals the opportunity to share their experiences to help others.