Snow loads on agricultural and other building structures
Snowfalls in 2010, and in the early part of 2011, caused a significant number of agricultural and associated buildings in Scotland, and a small number in the North of England, to partially fail or to collapse.
1 March 2011
CROSS Safety Alert
Region: CROSS-UK, CROSS-AUS, CROSS-US
Underpinning using screw piles
A reporter is concerned that inclined screw piles used for underpinning may be subjected to significant bending moments that compromise their capacity.
7 November 2023
CROSS Safety Report
Report ID: 1175
Region: CROSS-AUS
Wind adjacent to tall buildings
Reports to CROSS have raised concerns about the design of temporary works to resist wind loading in urban environments.
1 December 2015
CROSS Safety Alert
Region: CROSS-UK, CROSS-AUS, CROSS-US
Incorrect use of software for wind loads on solar panels
A reporter is concerned about designers relying completely on the output of software for structural analysis when they do not fully understand the requirements for data input.
7 November 2023
CROSS Safety Report
Report ID: 1212
Region: CROSS-AUS
Structural safety of glass in balustrades
Barriers in buildings may include balustrading, internal partitions and the external façade. Glass is commonly used as an infill or even as a structural component in all of these applications.
1 December 2019
CROSS Safety Alert
Region: CROSS-UK, CROSS-AUS, CROSS-US
Structural safety when designing lean in the climate emergency
The IStructE Safety, Health and Wellbeing Panel considers the safety implications when aspiring to a lean design.
4 January 2021
Third party content
Publisher: The Institution of Structural Engineers
High rise balustrade design
Wind loads used in design of balustrades on high-rise buildings (particularly those with glass infill panels) may need to be increased around the edges of the building.
1 August 2020
CROSS Safety Report
Report ID: 938
Region: CROSS-AUS