Safety information search results
Filter your results
Building or structure type
- Bridges (44)
- Buildings
(376)
- Agricultural buildings (8)
- Commercial (31)
- Consequence Class 3 buildings (3)
- Education, science & art buildings (23)
- Health care (7)
- Higher-risk buildings (5)
- Industrial buildings (14)
- LPS buildings (4)
- Public, religious & civic buildings (11)
- Recreational buildings (8)
- Residential (111)
- Stadiums (3)
- Storage buildings (10)
- Tall buildings (20)
- Theatres & other entertainment buildings (10)
- Transport buildings (5)
- Buried pipes & culverts (6)
- Car parks (15)
- Flats & apartments (40)
- Floating structures (1)
- Freestanding walls (4)
- Hotels & hostels (6)
- Houses (40)
- Marine structures (3)
- Masts & towers (15)
- Offshore structures (2)
- Railways (14)
- Reservoirs & dams (1)
- Retaining structures (33)
- Roads (10)
- Sewers (4)
- Temporary structures (39)
- Tunnels (3)
Materials
Project or lifecycle stage
Design
- BIM (3)
- Computational design (5)
- Design: quality management (55)
- Design calculations (64)
- Design conceptualisation (9)
- Design detailing (88)
- Design drawings (27)
- Design loads (94)
- Design software (26)
- Dynamics (9)
- Fire safety design (16)
- Resilience (20)
- Robustness (43)
- Structural design (108)
- Sustainability (6)
Codes, standards & regulations
Fire incident response
Project type
- Alteration & conversion project (33)
- Assessment project [sub-heading only] (13)
- Conservation & restoration project (1)
- Construction project [sub-heading only] (222)
- Demolition project (14)
- Excavation (15)
- Extension project (17)
- Fire safety assessment (2)
- Groundworks project (1)
- Maintenance project (3)
- New build (113)
- Refurbishment (11)
- Remediation project (20)
- Repair project (6)
- Strengthening project (10)
- Structural assessment (19)
- Underpinning project (4)
Construction period
Method of construction
Elements & systems
- Arch (7)
- Balconies (13)
- Balustrades (16)
- Basements (11)
- Beams (79)
- Bracing (21)
- Cables (2)
- Canopies (6)
- Ceilings (23)
- Cladding (28)
- Columns (44)
- Fasteners & connections (143)
- Fences (1)
- Fire exit doors (2)
- Fire protection (12)
- Foundations (38)
- Insulation (8)
- Light gauge steel framing (8)
- Lintels (4)
- Padstones (5)
- Parapets (11)
- PV panels (1)
- Roofs (59)
- Sandwich panels (1)
- Shear walls (3)
- Signs (5)
- Slabs (50)
- Tendons (1)
- Trusses (9)
- Wall head restraints (3)
- Walls (102)
- Wall ties (10)
- Wind posts (1)
Plant & equipment
Weather & natural hazards
Utilities
Safety reporting
Organisations
Business practice
Content type
- CROSS-AUS Newsletter 1 (2)
- CROSS-AUS Newsletter 2 (6)
- CROSS-AUS Newsletter 3 (6)
- CROSS-AUS Newsletter 4 (6)
- CROSS-AUS Newsletter 5 (4)
- CROSS-AUS [sub-heading only] (19)
- CROSS-UK Newsletter 1 (16)
- CROSS-UK Newsletter 2 (10)
- CROSS-UK Newsletter 3 (4)
- CROSS-UK Newsletter 4 (9)
- CROSS-UK Newsletter 5 (7)
- CROSS-UK Newsletter 6 (7)
- CROSS-UK Newsletter 7 (5)
- CROSS-UK Newsletter 8 (6)
- CROSS-UK Newsletter 9 (6)
- CROSS-UK Newsletter 10 (7)
- CROSS-UK Newsletter 11 (5)
- CROSS-UK Newsletter 12 (8)
- CROSS-UK Newsletter 13 (6)
- CROSS-UK Newsletter 14 (5)
- CROSS-UK Newsletter 15 (6)
- CROSS-UK Newsletter 16 (6)
- CROSS-UK Newsletter 17 (6)
- CROSS-UK Newsletter 18 (5)
- CROSS-UK Newsletter 19 (6)
- CROSS-UK Newsletter 20 (6)
- CROSS-UK Newsletter 21 (5)
- CROSS-UK Newsletter 22 (5)
- CROSS-UK Newsletter 23 (8)
- CROSS-UK Newsletter 24 (4)
- CROSS-UK Newsletter 25 (3)
- CROSS-UK Newsletter 26 (5)
- CROSS-UK Newsletter 27 (3)
- CROSS-UK Newsletter 28 (5)
- CROSS-UK Newsletter 29 (6)
- CROSS-UK Newsletter 30 (8)
- CROSS-UK Newsletter 31 (6)
- CROSS-UK Newsletter 32 (8)
- CROSS-UK Newsletter 33 (9)
- CROSS-UK Newsletter 34 (7)
- CROSS-UK Newsletter 35 (8)
- CROSS-UK Newsletter 36 (8)
- CROSS-UK Newsletter 37 (8)
- CROSS-UK Newsletter 38 (8)
- CROSS-UK Newsletter 39 (8)
- CROSS-UK Newsletter 40 (7)
- CROSS-UK Newsletter 41 (7)
- CROSS-UK Newsletter 42 (10)
- CROSS-UK Newsletter 43 (7)
- CROSS-UK Newsletter 44 (7)
- CROSS-UK Newsletter 45 (7)
- CROSS-UK Newsletter 46 (7)
- CROSS-UK Newsletter 47 (8)
- CROSS-UK Newsletter 48 (7)
- CROSS-UK Newsletter 49 (8)
- CROSS-UK Newsletter 50 (8)
- CROSS-UK Newsletter 51 (9)
- CROSS-UK Newsletter 52 (8)
- CROSS-UK Newsletter 53 (6)
- CROSS-UK Newsletter 54 (9)
- CROSS-UK Newsletter 55 (7)
- CROSS-UK Newsletter 56 (7)
- CROSS-UK Newsletter 57 (7)
- CROSS-UK Newsletter 58 (9)
- CROSS-UK Newsletter 59 (7)
- CROSS-UK Newsletter 60 (7)
- CROSS-UK Newsletter 61 (4)
- CROSS-UK Newsletter 62 (9)
- CROSS-UK Newsletter 64 (9)
- CROSS-UK Newsletter 65 (8)
- CROSS-UK [sub-heading only] (393)
- CROSS-US Newsletter 1 (5)
- CROSS-US Newsletter 2 (6)
- CROSS-US Newsletter 3 (5)
- CROSS-US [sub-heading only] (10)
- CROSS Newsletter (454)
- (-) CROSS Safety Report (633)
- News (3)
- News [sub-heading only] (81)
- Safety information from CROSS [sub-heading only] (3)
- Safety information [sub-heading only] (4)
CROSS regions
Stone cladding panel concerns
A reporter is concerned in respect of the risk of failure of stone cladding panels.
9 August 2022
CROSS Safety Report
Report ID: 1069
Region: CROSS-UK
Construction products- fire test certificates
A reporter has notified CROSS-AUS regarding the potentially inappropriate use of fire test methods on certain materials.
2 August 2022
CROSS Safety Report
Report ID: 1060
Region: CROSS-AUS
Modelling of structures
The reporter is concerned that some structural engineers assume without adequate verification that their computer modelling is correct and accurate; that they do not understand the limitations or basis for their modelling; or that the model chosen may not be appropriate for that structure.
2 August 2022
CROSS Safety Report
Report ID: 994
Region: CROSS-AUS
Continuously threaded reinforcing bar
Difficulties with site inspection of continuously threaded reinforcing bars
2 August 2022
CROSS Safety Report
Report ID: 1074
Region: CROSS-AUS
Site testing of post-installed fasteners in concrete
This report describes a situation where site testing of post-installed fasteners in concrete was undertaken by a contractor as an alternative to adopting the design data from the manufacturer in an attempt to justify an increased design capacity for the fasteners.
2 August 2022
CROSS Safety Report
Report ID: 1091
Region: CROSS-AUS
Precast concrete panel fixing
A 1960s flyover was being demolished and an interesting feature came to light how the precast concrete edge panels were fixed.
30 June 2022
CROSS Safety Report
Report ID: 965
Region: CROSS-UK
Share your knowledge
Your report will make a difference. It will help to create positive change and improve safety.
Our secure and confidential safety reporting system gives professionals the opportunity to share their experiences to help others.
Roof collapse at a social club
This is a report about a roof collapse that occurred, in about 1985, because only half as many parallel faced timber roof trusses were installed as there should have been.
30 June 2022
CROSS Safety Report
Report ID: 942
Region: CROSS-UK
Trench sheet naming confusion
A reporter involved with temporary works design has been made aware that there are two suppliers providing a trench sheet under the same name.
30 June 2022
CROSS Safety Report
Report ID: 814
Region: CROSS-UK
Galvanic (bimetallic) corrosion not considered in cladding design
A cladding designer and installer did not consider galvanic (bimetallic) corrosion which led to remedial works being required.
30 June 2022
CROSS Safety Report
Report ID: 811
Region: CROSS-UK
Failure of vertical bracing system in coffee shop
A reporter noticed that a bolt at a low level connecting node of the vertical bracing system in a public building had failed.
30 June 2022
CROSS Safety Report
Report ID: 759
Region: CROSS-UK