Fire in multi-storey car parks
The severe fire at the Liverpool Echo Arena MSCP on 31st December 2017 gutted the seven-storey building and up to 1,400 cars were destroyed.
1 February 2018
CROSS Safety Alert
Region: CROSS-UK, CROSS-AUS, CROSS-US
Tension systems and post-drilled fixings
Lining failures occurred in the Boston (Big Dig) tunnel in 2006, in the Balcome rail tunnel in the UK in 2011 and in Japan’s Sasago tunnel (2012); all related to the use of unsuitable fixings.
1 March 2014
CROSS Safety Alert
Region: CROSS-UK, CROSS-AUS, CROSS-US
Tension cable and rod connectors
In a number of instances, suspension fork connectors for high strength steel bars (cables or rods) acting in tension have failed at loads well below the intended design capacity or have been found to be substandard either during construction or in service.
1 August 2012
CROSS Safety Alert
Region: CROSS-UK, CROSS-AUS, CROSS-US
Aerated concrete slabs
A reporter discusses the failure of precast reinforced autoclaved aerated concrete (RAAC) slabs during construction.
1 October 2007
CROSS Safety Report
Report ID: 55
Region: CROSS-UK, CROSS-AUS, CROSS-US
Structural safety of glass in balustrades
Barriers in buildings may include balustrading, internal partitions and the external façade. Glass is commonly used as an infill or even as a structural component in all of these applications.
1 December 2019
CROSS Safety Alert
Region: CROSS-UK, CROSS-AUS, CROSS-US
Steel column erection anchoring connection failure injured worker
This report describes how a construction worker was injured during the erection of a steel column due to shortcomings in erection procedures and inadequacies in a column base connection.
10 May 2021
CROSS Safety Report
Report ID: 992
Region: CROSS-US
Failures of cold formed steel floor systems during construction
This report describes numerous collapses during construction of cold formed steel floor systems caused by lack of bracing/fastening and overloading of an incomplete structure.
10 May 2021
CROSS Safety Report
Report ID: 997
Region: CROSS-US
The selection and installation of construction fixings
SCOSS has been concerned for some time at the use of structural fixings where these so called minor items have not received the attention they deserve given their safety critical nature.
1 September 2010
CROSS Safety Alert
Region: CROSS-UK, CROSS-AUS, CROSS-US
Snow loads on agricultural and other building structures
Snowfalls in 2010, and in the early part of 2011, caused a significant number of agricultural and associated buildings in Scotland, and a small number in the North of England, to partially fail or to collapse.
1 March 2011
CROSS Safety Alert
Region: CROSS-UK, CROSS-AUS, CROSS-US
Essential consideration of ‘soft hazards’ on civil and building engineering projects
A check-list for all those engaged in structural or fire engineering design.