Safety information search results
Filter your results
Building or structure type
- Bridges (13)
- Buildings
(87)
- Car parks (3)
- Commercial (6)
- Education, science & art buildings (4)
- Health care (4)
- Higher-risk buildings (1)
- Industrial buildings (5)
- Public, religious & civic buildings (5)
- Recreational buildings (4)
- Residential (29)
- Storage buildings (3)
- Tall buildings (3)
- Theatres & other entertainment buildings (2)
- Transport buildings (1)
- Floating structures (1)
- Freestanding walls (2)
- Marine structures (2)
- Masts & towers (4)
- Railways (3)
- Retaining structures (8)
- Temporary structures (3)
Materials
Project or lifecycle stage
Design
Codes, standards & regulations
Fire incident response
Construction period
Method of construction
Elements & systems
- Arch (2)
- Balconies (2)
- Balustrades (4)
- Basements (3)
- Beams (8)
- Bracing (2)
- Canopies (1)
- Ceilings (2)
- Cladding (13)
- Columns (6)
- Fasteners & connections (26)
- Fences (1)
- Fire exit doors (1)
- Fire protection (3)
- Foundations (5)
- Insulation (1)
- Light gauge steel framing (3)
- Lintels (1)
- Padstones (1)
- Parapets (2)
- PV panels (1)
- Roofs (12)
- Shear walls (1)
- Slabs (9)
- Trusses (3)
- Walls (18)
- Wall ties (2)
Plant & equipment
Utilities
Safety reporting
Organisations
Project delivery methods
Business practice
Content type
- CROSS-AUS Newsletter 5 (4)
- CROSS-AUS Newsletter 8 (1)
- CROSS-UK Newsletter 61 (4)
- CROSS-UK Newsletter 62 (9)
- CROSS-UK Newsletter 64 (5)
- CROSS-UK Newsletter 65 (3)
- CROSS-UK Newsletter 67 (5)
- CROSS-UK Newsletter 68 (1)
- CROSS-US Newsletter 3 (5)
- CROSS Newsletter (11)
- (-) CROSS Safety Report (132)
- Safety information from CROSS [sub-heading only] (1)
- Safety information [sub-heading only] (4)
CROSS regions
Overall stability of building proposed to be provided by metal framing and plasterboard
Metal framing and plasterboard was used to provide lateral stability to a building. The form of construction was later deemed to be unsuitable and extensive remedial works had to be carried out.
24 May 2023
CROSS Safety Report
Report ID: 468
Region: CROSS-UK
Collapse of brick arch overbridge during demolition
A reporter describes a project where a flanking brick arch collapsed during the demolition of two multi-span bridges over rail lines.
30 June 2022
CROSS Safety Report
Report ID: 573
Region: CROSS-UK
Failure of cast-in wire lifting loops on manhole cover slabs
A cast-in wire lifting loop failed when lifting a 4m diameter precast manhole cover slab into place.
23 May 2022
CROSS Safety Report
Report ID: 629
Region: CROSS-UK
Behaviour of Phase Change Materials in fire when incorporated in linings in buildings
A reporter raised a concern regarding the perception and use of products that incorporate Phase Change Materials (PCMs).
24 May 2023
CROSS Safety Report
Report ID: 698
Region: CROSS-UK
Fatigue failure of bridge cross-girder
During a planned examination of a bridge, a cross-girder was found to have failed via fatigue.
23 May 2022
CROSS Safety Report
Report ID: 743
Region: CROSS-UK
Corrosion of main girder beam on bridge supporting rail lines
A hole was found in the central main girder on a bridge supporting rail line during inspection works.
23 May 2022
CROSS Safety Report
Report ID: 745
Region: CROSS-UK
Corrosion of steel truss footbridge
Severe corrosion was found in a steel truss footbridge during a planned examination.
23 May 2022
CROSS Safety Report
Report ID: 774
Region: CROSS-UK
Retaining wall collapses onto rail track
A retaining wall failed and collapsed onto a railway track.
1 June 2022
CROSS Safety Report
Report ID: 775
Region: CROSS-UK
Failure of vertical bracing system in coffee shop
A reporter noticed that a bolt at a low level connecting node of the vertical bracing system in a public building had failed.
30 June 2022
CROSS Safety Report
Report ID: 759
Region: CROSS-UK
Dangerous defects in curtain wall glazing
This report concerns a 5m high vertical glazing system in which the fixings for a panel failed after only four years because of a lack of co-ordination between designers and contractors.
6 April 2023
CROSS Safety Report
Report ID: 762
Region: CROSS-UK
Submit a report