Safety information search results
Filter your results
Building or structure type
- (-)
Buildings
(56)
- Car parks (9)
- Commercial (4)
- Education, science & art buildings (7)
- Health care (1)
- Higher-risk buildings (1)
- Industrial buildings (2)
- LPS buildings (1)
- Public, religious & civic buildings (3)
- Recreational buildings (4)
- Residential (7)
- Tall buildings (3)
- Theatres & other entertainment buildings (1)
- Transport buildings (4)
- Freestanding walls (2)
- Masts & towers (1)
- Railways (1)
- Retaining structures (1)
- Temporary structures (1)
Building height
Products
Project or lifecycle stage
Codes, standards & regulations
Fire incident response
Project type
- Alteration & conversion project (1)
- Assessment project [sub-heading only] (12)
- Conservation & restoration project (1)
- Construction project [sub-heading only] (8)
- Fire safety assessment (1)
- Maintenance project (1)
- New build (3)
- Refurbishment (2)
- Remediation project (7)
- Repair project (2)
- Structural assessment (18)
Construction period
Method of construction
Structural form
Elements & systems
- Arch (1)
- Balconies (4)
- Balustrades (2)
- Basements (1)
- Beams (3)
- Bracing (2)
- Cables (1)
- Canopies (2)
- Ceilings (4)
- Cladding (8)
- Columns (2)
- Fasteners & connections (12)
- Fences (1)
- Fire protection (1)
- Foundations (1)
- Insulation (1)
- Lintels (1)
- Parapets (3)
- Roofs (18)
- Signs (1)
- Slabs (10)
- Tendons (1)
- Trusses (2)
- Walls (8)
- Wall ties (1)
Temporary works
Plant & equipment
Utilities
Safety reporting
Project delivery methods
Business practice
Risk management
Content type
- CROSS-UK Newsletter 1 (1)
- CROSS-UK Newsletter 3 (1)
- CROSS-UK Newsletter 5 (1)
- CROSS-UK Newsletter 6 (1)
- CROSS-UK Newsletter 12 (1)
- CROSS-UK Newsletter 15 (1)
- CROSS-UK Newsletter 20 (1)
- CROSS-UK Newsletter 25 (1)
- CROSS-UK Newsletter 26 (3)
- CROSS-UK Newsletter 29 (1)
- CROSS-UK Newsletter 33 (2)
- CROSS-UK Newsletter 38 (1)
- CROSS-UK Newsletter 40 (1)
- CROSS-UK Newsletter 41 (1)
- CROSS-UK Newsletter 42 (1)
- CROSS-UK Newsletter 43 (1)
- CROSS-UK Newsletter 51 (1)
- CROSS-UK Newsletter 53 (1)
- CROSS-UK Newsletter 56 (1)
- CROSS-UK Newsletter 57 (1)
- CROSS-UK Newsletter 58 (1)
- CROSS-UK Newsletter 59 (1)
- CROSS-UK Newsletter 62 (1)
- CROSS-UK Newsletter 64 (1)
- CROSS-UK Newsletter 65 (2)
- CROSS-UK [sub-heading only] (22)
- CROSS-US Newsletter 1 (1)
- CROSS-US [sub-heading only] (1)
- CROSS Newsletter (12)
- CROSS Safety Alert (1)
- CROSS Safety Report (54)
- CROSS Topic Paper (1)
- News [sub-heading only] (5)
- Safety information from CROSS [sub-heading only] (1)
- Safety information [sub-heading only] (1)
CROSS regions
Rotting plywood decking on grandstand
During visual structural inspections of temporary demountable grandstands, a walkway board failed when it was walked on.
31 May 2022
CROSS Safety Report
Report ID: 1092
Region: CROSS-UK
Vegetation damage to railway arches
Lack of clarity as to maintenance responsibilities leads to degradation of railway arches.
6 June 2022
CROSS Safety Report
Report ID: 1064
Region: CROSS-UK
Another example of brick slips falling from height
Another example of defective brick slips falling from the facade of a building.
10 March 2022
CROSS Safety Report
Report ID: 1081
Region: CROSS-UK
Water ingress to cross-laminated timber structural frame
In an eight year old building that included cross-laminated timber construction, it was found that water penetration had caused parts of the structure to rot.
6 June 2022
CROSS Safety Report
Report ID: 1124
Region: CROSS-UK
Reinforced aerated autoclaved concrete planks found on pitched roof of 1990s hospital building
A building constructed in the early 1990s has been found to contain reinforced aerated autoclaved concrete (RAAC) planks. This date is important since it is much later than the previously thought last significant use of RAAC in buildings in the UK and potentially affects the scope of buildings that could require screening for RAAC problems.
26 August 2022
CROSS Safety Report
Report ID: 1125
Region: CROSS-UK
Collapse of folded plate timber roof at a school
This report is about a critical safety issue concerning folded timber roofs, in various settings, including over school halls.
18 October 2023
CROSS Safety Report
Report ID: 1160
Region: CROSS-UK
Failure of cantilevered stone staircase
During the renovation and change-of-use conversion of a former minor stately home built around 1830, under pedestrian loading, a ‘cantilevered’ stone staircase partially collapsed without warning.
21 February 2023
CROSS Safety Report
Report ID: 1147
Region: CROSS-UK
RAAC planks in a 1970s shopping centre
An existing large shopping centre built circa 1975 had a number of external storerooms and loading bays with roofs constructed using reinforced autoclaved aerated concrete (RAAC) planks. The planks had deflected to the extent that they needed replacing.
20 February 2023
CROSS Safety Report
Report ID: 1155
Region: CROSS-UK
Risks associated with historic stone balconies
A reporter highlights the structural issues of a stone balcony they encountered when working on a Grade II listed terrace house.
13 December 2021
CROSS Safety Report
Report ID: 1001
Region: CROSS-UK
Delay by party wall surveyor adds to risk
A party wall surveyor causes delay which prevents a dangerous wall from being made safe in a timely manner.