Safety information search results
Filter your results
Building or structure type
- Bridges (18)
- (-)
Buildings
(525)
- Agricultural buildings (9)
- Car parks (18)
- Commercial (50)
- Consequence Class 3 buildings (3)
- Education, science & art buildings (39)
- Health care (16)
- Higher-risk buildings (6)
- Industrial buildings (23)
- Laboratory buildings (1)
- LPS buildings (3)
- Nuclear & energy buildings (2)
- Public, religious & civic buildings (14)
- Recreational buildings (9)
- Residential (158)
- Stadiums (6)
- Storage buildings (11)
- Tall buildings (23)
- Theatres & other entertainment buildings (11)
- Transport buildings (6)
- Buried pipes & culverts (1)
- Floating structures (1)
- Freestanding walls (3)
- Marine structures (2)
- Masts & towers (4)
- Railways (4)
- Reservoirs & dams (1)
- Retaining structures (11)
- Roads (2)
- Sewers (1)
- Temporary structures (7)
Building height
Materials
Project or lifecycle stage
Design
- BIM (3)
- Computational design (11)
- Design: quality management (45)
- Design calculations (54)
- Design conceptualisation (29)
- Design detailing (91)
- Design drawings (27)
- Design loads (81)
- Design software (22)
- Dynamics (10)
- Fire safety design (15)
- Resilience (19)
- Robustness (49)
- Structural design (89)
- Sustainability (6)
Codes, standards & regulations
Fire incident response
Project type
- Alteration & conversion project (39)
- Assessment project [sub-heading only] (18)
- Conservation & restoration project (3)
- Construction project [sub-heading only] (182)
- Demolition project (11)
- Excavation (7)
- Extension project (19)
- Fire safety assessment (2)
- Groundworks project (1)
- Maintenance project (3)
- New build (87)
- Refurbishment (19)
- Remediation project (20)
- Repair project (7)
- Strengthening project (6)
- Structural assessment (27)
- Underpinning project (4)
Construction period
Method of construction
Elements & systems
- Arch (2)
- Balconies (18)
- Balustrades (20)
- Basements (13)
- Beams (55)
- Bracing (17)
- Cables (1)
- Canopies (8)
- Ceilings (23)
- Cladding (35)
- Columns (38)
- Fasteners & connections (111)
- Fences (1)
- Fire exit doors (2)
- Fire protection (15)
- Foundations (22)
- Insulation (10)
- Light gauge steel framing (7)
- Lintels (4)
- Padstones (5)
- Parapets (10)
- PV panels (3)
- Roofs (79)
- Sandwich panels (3)
- Shear walls (4)
- Signs (2)
- Slabs (48)
- Tendons (2)
- Trusses (10)
- Wall head restraints (3)
- Walls (73)
- Wall ties (14)
- Wind posts (1)
Plant & equipment
Utilities
Safety reporting
Organisations
Business practice
Content type
- CROSS-AUS Newsletter 1 (1)
- CROSS-AUS Newsletter 2 (2)
- CROSS-AUS Newsletter 3 (2)
- CROSS-AUS Newsletter 8 (2)
- CROSS-AUS [sub-heading only] (4)
- CROSS-UK Newsletter 1 (6)
- CROSS-UK Newsletter 2 (6)
- CROSS-UK Newsletter 3 (3)
- CROSS-UK Newsletter 4 (2)
- CROSS-UK Newsletter 5 (6)
- CROSS-UK Newsletter 6 (5)
- CROSS-UK Newsletter 7 (5)
- CROSS-UK Newsletter 8 (2)
- CROSS-UK Newsletter 9 (4)
- CROSS-UK Newsletter 10 (6)
- CROSS-UK Newsletter 11 (3)
- CROSS-UK Newsletter 12 (7)
- CROSS-UK Newsletter 13 (4)
- CROSS-UK Newsletter 14 (2)
- CROSS-UK Newsletter 15 (3)
- CROSS-UK Newsletter 17 (4)
- CROSS-UK Newsletter 18 (2)
- CROSS-UK Newsletter 19 (4)
- CROSS-UK Newsletter 20 (6)
- CROSS-UK Newsletter 21 (4)
- CROSS-UK Newsletter 22 (1)
- CROSS-UK Newsletter 23 (7)
- CROSS-UK Newsletter 24 (2)
- CROSS-UK Newsletter 25 (2)
- CROSS-UK Newsletter 26 (5)
- CROSS-UK Newsletter 28 (1)
- CROSS-UK Newsletter 29 (2)
- CROSS-UK Newsletter 30 (3)
- CROSS-UK Newsletter 31 (5)
- CROSS-UK Newsletter 32 (5)
- CROSS-UK Newsletter 33 (7)
- CROSS-UK Newsletter 34 (4)
- CROSS-UK Newsletter 35 (4)
- CROSS-UK Newsletter 36 (2)
- CROSS-UK Newsletter 37 (5)
- CROSS-UK Newsletter 38 (4)
- CROSS-UK Newsletter 39 (4)
- CROSS-UK Newsletter 40 (4)
- CROSS-UK Newsletter 41 (6)
- CROSS-UK Newsletter 42 (4)
- CROSS-UK Newsletter 43 (4)
- CROSS-UK Newsletter 44 (2)
- CROSS-UK Newsletter 45 (4)
- CROSS-UK Newsletter 46 (4)
- CROSS-UK Newsletter 47 (6)
- CROSS-UK Newsletter 48 (6)
- CROSS-UK Newsletter 49 (6)
- CROSS-UK Newsletter 50 (6)
- CROSS-UK Newsletter 51 (6)
- CROSS-UK Newsletter 52 (3)
- CROSS-UK Newsletter 53 (3)
- CROSS-UK Newsletter 54 (6)
- CROSS-UK Newsletter 55 (5)
- CROSS-UK Newsletter 56 (4)
- CROSS-UK Newsletter 57 (4)
- CROSS-UK Newsletter 58 (8)
- CROSS-UK Newsletter 59 (4)
- CROSS-UK Newsletter 60 (6)
- CROSS-UK Newsletter 61 (3)
- CROSS-UK Newsletter 62 (7)
- CROSS-UK Newsletter 64 (9)
- CROSS-UK Newsletter 65 (8)
- CROSS-UK Newsletter 67 (10)
- CROSS-UK Newsletter 68 (9)
- CROSS-UK [sub-heading only] (231)
- CROSS-US Newsletter 1 (3)
- CROSS-US Newsletter 2 (6)
- CROSS-US Newsletter 3 (5)
- CROSS-US [sub-heading only] (8)
- CROSS Feature Article (1)
- CROSS Newsletter (141)
- CROSS Safety Alert (12)
- CROSS Safety Report (493)
- CROSS Theme Page (1)
- CROSS Topic Paper (9)
- News [sub-heading only] (45)
- Safety information from CROSS [sub-heading only] (4)
- Safety information [sub-heading only] (5)
- Third party content (9)
- Third party content (5)
CROSS regions
Inadequate structural design on industrial steel structures
A reporter's firm believes that steel structures associated with plant are being erected without a design being carried out by a structural engineer and are therefore potentially dangerous.
1 April 2019
CROSS Safety Report
Report ID: 804
Region: CROSS-UK
Weld de-specification without design approval
A reporter's firm was engaged as fabricators for a main contractor and asked by them to de-specify full and partial penetration butt welds and replace them with fillet welds without approval from the main design engineer.
14 October 2020
CROSS Safety Report
Report ID: 845
Region: CROSS-UK
Safety concern about the design of thin concrete walls
The reporter raises their concern about the design of thin concrete load-bearing walls, sometimes supporting 10 or more storeys.
1 July 2019
CROSS Safety Report
Report ID: 815
Region: CROSS-AUS
Design responsibility for temporary stability of steel frame building
A reporter raises concerns about the division of responsibility for the temporary stability of a four-storey steel frame structure with precast concrete planks and a structural topping.
1 April 2019
CROSS Safety Report
Report ID: 789
Region: CROSS-UK
Unauthorised structural alterations to accommodate drainpipes
A reporter became aware of cases where main structural steel sections were ‘butchered’ on site to accommodate drainpipes.
1 July 2020
CROSS Safety Report
Report ID: 902
Region: CROSS-UK
Structural issues with cladding
A reporter who investigates cladding failures shares common issues they have encountered.
1 April 2020
CROSS Safety Report
Report ID: 904
Region: CROSS-UK
High rise balustrade design
Wind loads used in design of balustrades on high-rise buildings (particularly those with glass infill panels) may need to be increased around the edges of the building.
1 August 2020
CROSS Safety Report
Report ID: 938
Region: CROSS-AUS
Failure of RAAC planks in schools
A reporter was asked to investigate a reinforced autoclaved aerated concrete (RAAC) roof which had collapsed in a school.
1 April 2020
CROSS Safety Report
Report ID: 908
Region: CROSS-UK, CROSS-AUS, CROSS-US
Missing punching shear reinforcement in concrete slabs
A reporter raises concerns of how two separate engineers observed the omission of design punching shear reinforcement prior to slab pours being undertaken on two different sites.
1 April 2020
CROSS Safety Report
Report ID: 906
Region: CROSS-UK
Fire risks in multi-storey car parks
A reporter is concerned by the reluctance of the industry to voluntarily take on board and proactively react to the lessons learnt from the fire at the Echo Arena car park in Liverpool.
14 October 2020
CROSS Safety Report
Report ID: 940
Region: CROSS-UK